 Subtask 32-51-00-865-081
 D. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU HYDRAULIC/BRAKING AND STEERING/SYS1/CTL 1GG M34 121VU HYDRAULIC/BRAKING AND STEERING/SYS1/IND AND/SPLY 2GG M33
 4. Procedure
_________
 (Ref. Fig. 511/TASK 32-51-00-991-014, 512/TASK 32-51-00-991-015, 513/TASK
 32-51-00-991-016)
 NOTE : The voltages U1 and U2 are in volts (3V approximately).

____

R 1EFF : 001-004, 051-054, 1 32-51-00Page A509 1 1 Aug 01/05 1 1 1CES 1


 Adjustment of the NWS Position - Sensor P/N C24763000, NLG Cams as reference Figure 511/TASK 32-51-00-991-014
R 1EFF : 001-004, 051-054, 1 32-51-00Page A510 1 1 Aug 01/05 1 1 1CES 1


 Adjustment of the Gear Box P/N C24764000 with tool M46196, NLG Cams as
 reference
 Figure 512/TASK 32-51-00-991-015

R 1EFF : 001-004, 051-054, 1 32-51-00Page A511 1 1 Aug 01/05 1 1 1CES 1


 Calculated Chart - Gear Box P/N C24764000 with tool M46196, NLG Cams as
 reference
 Figure 513/TASK 32-51-00-991-016

R 1EFF : 001-004, 051-054, 1 32-51-00Page A512 1 1 Aug 01/05 1 1 1CES 1 Subtask 32-51-00-220-053


 A. Check of the play on the NLG cams
 (1)
 On the panel 402VU, put the A/SKID & N/W STRG switch in OFF position.

 (2)
 Disconnect the connector (3) from the RVDT 3GC (1).

 (3)
 Connect the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST (F26792000-1) (2) between the connector (3) and the RVDT 3GC (1).

 (4)
 On the panel 402VU, put the A/SKID & N/W STRG switch in ON position.

 (5)
 Connect a AC voltmeter (minimum range: 0-20V, accuracy: 1 mV, frequency: 50-2000 Hz) to the SECONDARY VOLTAGE connections on the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST.

 (6)
 Check of the play on the NLG cams

 (a)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST set the selector switch to U1.

 (b)
 Manually move the wheels in steering mode on the RH stop. Record the voltage U1.

 (c)
 Manually move the wheels in steering mode on the LH stop. Record the voltage U1'.

 (d)
 From the voltage U1 and U1', calculate the average voltage U1".

 (e)
 Manually move the wheels in steering mode to get the voltage U1". NOTE : The angular travel of the nose wheels includes the NLG cam

 


____ play and the NLG torque link play.
 Subtask 32-51-00-820-058
 B. Set the NWS Zero Position
 NOTE : The adjustment process is very sensitive.

____
 NOTE : Do not move the wheels manually in the steering mode when you do

____
 the adjustment procedure.

R 1EFF : 001-004, 051-054, 1 32-51-00Page A513 1 1 Aug 01/05 1 1 1CES 1


 (1)
 Stage 1:

 (a)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (2) set the selector switch to U1.

 (b)
 Record the voltage (U1).

 (c)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (2) set the selector switch to U2.

 (d)
 Record the voltage (U2).

 (e)
 From the voltages U1 and U2, calculate the voltage U:
 U = U1 - U2

 


 (2)
 If the voltage U is not equal to 0 +/- 20mV, adjust the gear box:

 (a)
 Remove the RVDT 3GC (1) (Ref. TASK 32-51-19-000-001).

 (b)
 Install the ASSEMBLY TOOL (M46196) on the gearbox, put the stud

 (15) of the rigging tool M46196-2 (14) in the drive slot (13) of the gearbox plate (11).

 (c)
 Hold the rigging tool M46196-2 (14) in position and loosen the screws (12).

 (d)
 Lightly move the gearbox plate (11) with the rigging tool M46196-2 (14):.

 -clockwise if the value U is less than minus 20mV
 -counterclochwise if the value U is more than plus 20mV

 (e)
 TORQUE the screws (12) to between 0.1 and 0.15 m.daN (8.84 and

 


 13.27 lbf.in).
 NOTE : Make sure that the gearbox plate (11) does not move when

____ you TORQUE the screws (12). If the gearbox plate (11) moves, the adjustment will not be correct.
 (f)
 Remove the rigging tool M46196-2 (14).

 (g)
 Install the RVDT 3GC (1) (Ref. TASK 32-51-19-400-001). NOTE : Lightly lubricate the packing of the sensor 3GC with
 