Subtask 32-31-00-480-057
R C. Installation of the Test Equipment
R (1) Connect the GROUND PRESSURE GENERATOR to the static and pitot probes
R as follows:
R (a) Connect the ADAPTER COVER-STATIC PORT equipment to the static
R probes 7DA2 and 8DA2.
R (b) Connect the ADAPTOR-CHARGING,PITOT PROBE to the pitot probe 9DA2.
R (c) Seal the drain holes of the pitot probe 9DA2 with colored
R adhesive tape.
R CAUTION : WHEN YOU SEAL THE DRAIN HOLE IN THE PITOT PROBE, DO NOT_______
R SEAL THE HOLE DIRECTLY WITH THE COLORED ADHESIVE TAPE.
R ALWAYS PUT A PIECE OF PLASTIC ON THE HOLE AND USE THE
R TAPE TO ATTACH THE PLASTIC.
R IF YOU SEAL THE DRAIN HOLE DIRECTLY WITH THE ADHESIVE
R TAPE, THERE IS A RISK THAT SOME OF THE ADHESIVE WILL
R STAY ON THE HOLE AND COLLECT PARTICLES. THIS CAN
R SUBSEQUENTLY CAUSE BLOCKAGE OF THE HOLE AND THUS
R INCORRECT OPERATION OF THE PROBE.
R (d) Move the vane of the AOA sensor 3FP2 to the top (nose-up)
R position. Keep the vane in this position with colored adhesive
R tape.
R
Subtask 32-31-00-720-060
R D. Operational Check to Ensure Safety Valve Closes at 260 kts
R CAUTION : OBEY THESE PRECAUTIONS WHEN YOU DO THE TEST TO PREVENT DAMAGE_______
R TO INSTRUMENTS:
R - PRESSURE SET MUST NOT BE MORE THAN 1050 hPa (31 in Hg) OR
R LESS THAN 115 hPa (3.39 in Hg)
R - CHANGES IN PRESSURE MUST NOT BE MORE THAN 6000 FEET/MINUTE
R - DO NOT SUDDENLY OPEN LINES TO AMBIENT AIR WHILE THE PRESSURE
R GENERATOR IS CONNECTED.
R CAUTION : THE TOTAL PRESSURE IN THE PITOT SYSTEM MUST NEVER BE LESS THAN_______
R THE STATIC PRESSURE. THE DIFFERENCE BETWEEN THE PITOT AND THE
R STATIC PRESSURE CIRCUITS MUST NEVER BE MORE THAN 368 hPa (10.86
R in Hg).
____ R procedures (Ref. TSM 32 PB 101).
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 20VU: R - set the IR 3 selector switch to R ATT to energize the ADIRU 3. R Reference Para. 4.A., do again R the test procedure steps 7. R thru 13.
2. On the panel 20VU:
-set the IR 3 selector switch to OFF.
3.
Make sure that the travel range of the applicable MLG door is clear.
4.
Try to move the applicable ground
door operating handle to the R CLOSE position. R R R R R R R
5.
Remove the FALSE TARGET from the applicable proximity sensor 21GA(20GA).
6.
Make sure that the travel range of the applicable MLG door is clear.
7.
Move the applicable ground door-operating handle to the CLOSE position.
The handle will not move.
NOTE : There can be unwanted movement
____ of the ground door-operating handle because of remaining green hydraulic pressure. If the handle can be moved more than five times, it is possible that the safety valve 49GA is defective.
The safety-valve 49GA is energized(valve OPEN).
The applicable MLG door closes.
1EFF : ALL 1 32-31-00Page 532 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 32-31-00Page 533 1 1 May 01/05 1 1 1CES 1 Subtask 32-31-00-869-098
5. Close-up________
Subtask 32-31-00-080-057
A. Removal of the Test Equipment
R R (1) Disconnect and remove the ADAPTOR-CHARGING,PITOT PROBE from the pitot probe 9DA2 and the GROUND PRESSURE GENERATOR.
R R (2) Disconnect and remove the ADAPTER COVER-STATIC PORT equipment from the static probes 7DA2 and 8DA2, and the GROUND PRESSURE GENERATOR.
R R (3) Remove the colored adhesive tape from the pitot probe 9DA2 drain holes and the AOA sensor 3FP2.
Subtask 32-31-00-410-065
B. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Make sure that the applicable MLG ground door-operating handle is locked in the CLOSED position.
(3) Close the applicable quick-release access panel 195BB, 196BB.
Subtask 32-31-00-860-080
C. Aircraft Maintenance Configuration