Subtask 32-31-00-480-057  
R  C. Installation of the Test Equipment  
R  (1) Connect the GROUND PRESSURE GENERATOR to the static and pitot probes  
R  as follows:  
R  (a) Connect the ADAPTER COVER-STATIC PORT equipment to the static  
R  probes 7DA2 and 8DA2.  
R  (b) Connect the ADAPTOR-CHARGING,PITOT PROBE to the pitot probe 9DA2.  
R  (c) Seal the drain holes of the pitot probe 9DA2 with colored  
R  adhesive tape.  
R  CAUTION : WHEN YOU SEAL THE DRAIN HOLE IN THE PITOT PROBE, DO NOT_______  
R  SEAL THE HOLE DIRECTLY WITH THE COLORED ADHESIVE TAPE.  
R  ALWAYS PUT A PIECE OF PLASTIC ON THE HOLE AND USE THE  
R  TAPE TO ATTACH THE PLASTIC.  
R  IF YOU SEAL THE DRAIN HOLE DIRECTLY WITH THE ADHESIVE  
R  TAPE, THERE IS A RISK THAT SOME OF THE ADHESIVE WILL  
R  STAY ON THE HOLE AND COLLECT PARTICLES. THIS CAN  
R  SUBSEQUENTLY CAUSE BLOCKAGE OF THE HOLE AND THUS  
R  INCORRECT OPERATION OF THE PROBE.  
R  (d) Move the vane of the AOA sensor 3FP2 to the top (nose-up)  
R  position. Keep the vane in this position with colored adhesive  
R  tape.  
R 
 Subtask 32-31-00-720-060  
R  D. Operational Check to Ensure Safety Valve Closes at 260 kts  
R  CAUTION : OBEY THESE PRECAUTIONS WHEN YOU DO THE TEST TO PREVENT DAMAGE_______  
R  TO INSTRUMENTS:  
R  - PRESSURE SET MUST NOT BE MORE THAN 1050 hPa (31 in Hg) OR  
R  LESS THAN 115 hPa (3.39 in Hg)  
R  - CHANGES IN PRESSURE MUST NOT BE MORE THAN 6000 FEET/MINUTE  
R  - DO NOT SUDDENLY OPEN LINES TO AMBIENT AIR WHILE THE PRESSURE  
R  GENERATOR IS CONNECTED.  
R  CAUTION : THE TOTAL PRESSURE IN THE PITOT SYSTEM MUST NEVER BE LESS THAN_______  
R  THE STATIC PRESSURE. THE DIFFERENCE BETWEEN THE PITOT AND THE  
R  STATIC PRESSURE CIRCUITS MUST NEVER BE MORE THAN 368 hPa (10.86  
R  in Hg).
____ R procedures (Ref. TSM 32 PB 101).
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 20VU: R - set the IR 3 selector switch to R ATT to energize the ADIRU 3. R Reference Para. 4.A., do again R the test procedure steps 7. R thru 13.
 2. On the panel 20VU:
 -set the IR 3 selector switch to OFF.
 3.
 Make sure that the travel range of the applicable MLG door is clear.
 4.
 Try to move the applicable ground
door operating handle to the R CLOSE position. R R R R R R R 
5.
 Remove the FALSE TARGET from the applicable proximity sensor 21GA(20GA).
 6.
 Make sure that the travel range of the applicable MLG door is clear.
 7.
 Move the applicable ground door-operating handle to the CLOSE position.
The handle will not move.
NOTE : There can be unwanted movement
____ of the ground door-operating handle because of remaining green hydraulic pressure. If the handle can be moved more than five times, it is possible that the safety valve 49GA is defective.
The safety-valve 49GA is energized(valve OPEN).
The applicable MLG door closes.
 1EFF : ALL 1 32-31-00Page 532 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 32-31-00Page 533 1 1 May 01/05 1 1 1CES 1 Subtask 32-31-00-869-098
 5. Close-up________ 
 Subtask 32-31-00-080-057 
 A. Removal of the Test Equipment  
R R  (1) Disconnect and remove the ADAPTOR-CHARGING,PITOT PROBE from the pitot probe 9DA2 and the GROUND PRESSURE GENERATOR.  
R R  (2) Disconnect and remove the ADAPTER COVER-STATIC PORT equipment from the static probes 7DA2 and 8DA2, and the GROUND PRESSURE GENERATOR.  
R R  (3) Remove the colored adhesive tape from the pitot probe 9DA2 drain holes and the AOA sensor 3FP2. 
 Subtask 32-31-00-410-065 
 B. Close Access 
 (1) Make sure that the work area is clean and clear of tool(s) and other items. 
 (2) Make sure that the applicable MLG ground door-operating handle is locked in the CLOSED position. 
 (3) Close the applicable quick-release access panel 195BB, 196BB. 