the dimension T is between 4.00 mm (0.1574 in.) and 6.00 mm (0.2362 in.),
-
the dimension U is between 8.5 mm (0.3346 in.) and 11.5 mm (0.4527 in.),
-
the dimension V is between 5.5 mm (0.2165 in.) and 8.5 mm (0.3346 in.),
-
the dimension W is between 7.5 mm (0.2952 in.) and 10.5 mm (0.4133 in.).
(4)
Open the door.
(5)
If necessary adjust the NLG doors (Ref. TASK 32-22-00-820-001).
R **ON A/C 062-099, 151-199, 204-212,
Subtask 32-22-11-220-050-A
D. Check of the NLG Door Gaps
(Ref. Fig. 402A/TASK 32-22-11-991-007-A)
(1)
Close the door (24) manually so that it touches the forward stop (25).
(2)
Hold the door (24) closed and measure the dimensions Q, R, S, T, U, V and W.
(3)
Make sure that:
-
the dimension Q is between 0.83 mm (0.0326 in.) and 2.83 mm (0.1114 in.),
-
the dimension R is between 2.5 mm (0.0984 in.) and 5.5 mm (0.2165 in.),
-
the dimension S is between 0 mm (0.0000 in.) and 1.4 mm (0.0551 in.),
-
the dimension T is between 4.00 mm (0.1574 in.) and 6.00 mm (0.2362 in.),
-
the dimension U is between 0 mm (0.0000 in.) and 3 mm (0.1181 in.),
-
the dimension V is between 5.5 mm (0.2165 in.) and 8.5 mm (0.3346 in.),
-
the dimension W is between 0 mm (0.0000 in.) and 3 mm (0.1181 in.).
(4)
Open the door.
(5)
If necessary adjust the NLG doors (Ref. TASK 32-22-00-820-001).
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 32-22-11Page 412 1201-212, 1May 01/05 1 1 1CES 1R **ON A/C 106-149, 213-299, 301-399, 401-499,
Subtask 32-22-11-220-050-B
D. Check of the NLG Door Gaps
(Ref. Fig. 402B/TASK 32-22-11-991-007-B)
(1)
Close the door (24) manually so that it touches the forward stop (25).
(2)
Hold the door (24) closed and measure the dimensions Q, R, S, T, U, V and W.
(3)
Make sure that:
-
the dimension Q is between 0.83 mm (0.0326 in.) and 2.83 mm (0.1114 in.),
-
the dimension R is between 2.5 mm (0.0984 in.) and 5.5 mm (0.2165 in.),
-
the dimension S is between 0 mm (0.0000 in.) and 1.4 mm (0.0551 in.),
-
the dimension T is between 4.00 mm (0.1574 in.) and 6.00 mm (0.2362 in.),
-
the dimension U is between 0 mm (0.0000 in.) and 3 mm (0.1181 in.),
-
the dimension V is between 5.5 mm (0.2165 in.) and 8.5 mm (0.3346 in.),
-
the dimension W is between 0 mm (0.0000 in.) and 3 mm (0.1181 in.).
(4)
Open the door.
(5)
If necessary adjust the NLG doors (Ref. TASK 32-22-00-820-001).
**ON A/C ALL
Subtask 32-22-11-869-050
E. Extend the NLG
(1)
Extend the landing gear as slowly as possible (Ref. TASK 32-30-00-867-002).
(2)
Put the access platform in position.
1EFF : ALL 1 32-22-11Page 413 1 1 Aug 01/05 1 1 1CES 1
NLG Main Doors
Figure 402A/TASK 32-22-11-991-007-A12 (SHEET 1)
R 1EFF : 062-099, 151-199, 204-212, 1 32-22-11Page 414 1 1 May 01/05 1 1 1CES 1
NLG Main Doors
Figure 402A/TASK 32-22-11-991-007-A22 (SHEET 2)
R 1EFF : 062-099, 151-199, 204-212, 1 32-22-11Page 415 1 1 May 01/05 1 1 1CES 1
NLG Main Doors
Figure 402B/TASK 32-22-11-991-007-B12 (SHEET 1)
R 1EFF : 106-149, 213-299, 301-399, 401-499, 1 32-22-11Page 416 1 1 Aug 01/05 1 1 1CES 1
NLG Main Doors
Figure 402B/TASK 32-22-11-991-007-B22 (SHEET 2)
R 1EFF : 106-149, 213-299, 301-399, 401-499, 1 32-22-11Page 417 1 1 Aug 01/05 1 1 1CES 1 Subtask 32-22-11-420-055
F. Connection of the NLG Door Rod
(1) Installation of the NLG main door control rod (Ref. TASK 32-31-41-400-001).
Subtask 32-22-11-420-053
G. Preparation for the Test
(1)
Install the proximity sensors (Ref. TASK 32-31-73-400-005).
(2)
Lubricate the NLG doors (Ref. TASK 12-22-32-640-002).
(3)
Remove the access platform(s).
(4)
Close the NLG doors:
(a)
Operate the NLG doors manually to make sure that there is no interference in the linkage.
(b)
Close the NLG doors (Ref. TASK 32-22-00-410-001).
(5)
Do a check of the NLG door gaps and mismatches (Ref. TASK 32-22-00-200-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架4(5)