Subtask 32-22-13-020-053
A. Removal of the Seals
(1)
Remove the six nuts (1) and the six bolts (18).
(2)
Remove the seal retainer (2), the seal (3) and the lightning arrestor strip (4).
(3)
Remove the two screws (12) and the seal retainer (6).
(4)
Remove the seal (5).
(5)
Remove the four screws (13) and the seal retainer assembly (7).
(6)
Remove the two screws (14) and the seal retainer assembly (8).
(7)
Remove the two screws (15) and the seal retainer assembly (10).
(8)
Remove the seal (9).
(9)
Remove the three screws (16) and the seal retainer assembly (11).
(10) Remove the seal (17).
1EFF : ALL 1 32-22-13Page 416 1 1 Aug 01/05 1 1 1CES 1
NLG Aft Door - Seals Figure 402/TASK 32-22-13-991-006
R 1EFF : 1 1 1CES ALL 1 111 32-22-13 Page 417 Nov 01/02
NLG Aft Door - Position of the Seals
Figure 403/TASK 32-22-13-991-007
R 1EFF : 001-049, 051-061, 101-105, 201-203, 1 32-22-13Page 418 1 1 May 01/05 1 1 1CES 1
NLG Aft Door - Position of the Seals
Figure 403A/TASK 32-22-13-991-007-A
R 1EFF : 062-099, 106-149, 151-199, 204-299, 1 32-22-13Page 419 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1R **ON A/C 001-049, 051-061, 101-105, 201-203,
Subtask 32-22-13-420-055
B. Installation of the Seal
(1)
Rub the zone B on which you apply the sealant with emery cloth.
(2)
Apply a layer of SEALANTS (Material No. 09-016) on the door zone B.
(3)
Put the seal (17) and the seal retainer assembly (11) in position.
(4)
Make sure that the end of the seal (17) is 10 +2.5 -2.5 mm (0.3937 +0.0984 -0.0984 in.) from the edge of the door.
(5)
Install the three screws (16).
(6)
TORQUE the screws (16) to 0.35 m.daN (30.97 lbf.in).
(7)
Put the seal (9) and the seal retainer assemblies (7), (8) and (10) in position.
(8)
Make sure that the end of the seal (9) is 10 +2.5 -2.5 mm (0.3937 +0.0984 -0.0984 in.) from the edge of the door.
(9)
Install the eight screws (13), (14) and (15).
(10)
TORQUE the screws (13), (14) and (15) to 0.35 m.daN (30.97 lbf.in).
(11)
Put the seal (5) and the seal retainer assemblies (6) in position.
(12)
Make sure that the end of the seal (5) is 10 +2.5 -2.5 mm (0.3937 +0.0984 -0.0984 in.) from the edge of the door.
(13)
Install the two screws (12).
(14)
TORQUE the screws (12) to 0.35 m.daN (30.97 lbf.in).
(15)
Put the lightning arrestor strip (4), the seal (3) and the seal retainer (2) in position.
(16)
Make sure that the end of the lightning arrestor strip (4) is 2 mm (0.0787 in.) from the edge of the door.
(17)
Install the six bolts (18) and the six nuts (1).
R 1EFF : 001-049, 051-061, 101-105, 201-203, 1 32-22-13Page 420 1 1 May 01/05 1 1 1CES 1
(18) TORQUE the nuts (1) to 0.35 m.daN (30.97 lbf.in). R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
Subtask 32-22-13-420-055-A
B. Installation of the Seal
(1)
Rub the zones B and C on which you apply the sealant with emery cloth.
(2)
Apply a layer of SEALANTS (Material No. 09-016) on the door zones B and C.
(3)
Put the seal (17) in position to get the dimension U to 0 mm (0.0000 in.).
(4)
Install the seal retainer assembly (11) and the screws (16).
(5)
Tighten but do not torque the screws (16).
(6)
Put the seal (9) in position to get the dimension S to 0 mm (0.0000 in.).
(7)
Install the seal retainer assemblies (7), (8) and (10) and the screws (13), (14) and (15).
(8)
Tighten but do not torque the screws (13), (14) and (15).
(9)
Put the seal (5) in position to get the dimension S to 0 mm (0.0000 in.).
(10)
Install the seal retainer assemblies (6) and the screws (12).
(11)
Tighten but do not torque the screws (12).
(12)
Put the lightning arrestor strip (4), the seal (3) and the seal retainer (2) in position.
(13)
Make sure that the end of the lightning arrestor strip (4) is 2 mm (0.0787 in.) from the edge of the door.
(14)
Install the six bolts (18) and the six nuts (1).
中国航空网 www.aero.cn