 When you have completed the refuel, keep the refuel panel door open and the MODE SEL switch (on the panel 800VU) in the REFUEL position.

 (3)
 Energize the ECAM system (Ref. TASK 31-60-00-860-001).

 (4)
 On the ECAM control panel, push (in) the FUEL pushbutton switch (P/BSW).

 (5)
 On the ECAM System Display (SD), make sure that the FUEL page is shown.

 (6)
 On the ECAM SD FUEL page, make sure that the intercell transfer valves show closed.


R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-15-00Page 502 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


 4. Procedure
_________
 Subtask 28-15-00-865-051
 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FUEL/XFR VALVE1/WING/R 2QP A11 49VU FUEL/XFR VALVE1/WING/L 1QP A10 121VU FUEL/XFR VALVE2/WING/R 4QP M23 121VU FUEL/XFR VALVE2/WING/L 3QP M22

R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
 Subtask 28-15-00-710-053
 B. Operational Check of Individual Transfer Valves to Ensure Drive Shaft Rotates Valve to Open Position
 NOTE : During the test the ECAM will show unwanted indications, which you
____
 can ignore.

 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. Open, safety and tag the circuit On the ECAM display unit (DU):
 breaker 3QP.  - the green right-wing transfer-valve indicator moves from the closed position to the open position
 -
the green left-wing transfer-valve indicator moves from the closed position to the intermediate (amber) position

 -
the right-wing outer-cell fuel content decreases and the right-wing inner-cell fuel content increases.


 2. Remove the safety-clip and tag  On the ECAM DU: and close the circuit breaker - the green right-wing transfer-valve 3QP. indicator moves from the open to the
 closed position
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-15-00Page 503 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- the amber left-wing transfer-valve indicator moves from the intermediate
 to the closed (green) position - the fuel movement to the right-wing inner-cell stops.
 3. Open, safety and tag the circuit breaker 4QP.  On the ECAM display unit (DU):- the green left-wing transfer-valve indicator moves from the closed
 position to the open position - the green right-wing transfer-valve indicator moves from the closed
 position to the intermediate (amber) position - the left-wing outer-cell fuel content decreases and the left-wing inner-cell fuel content increases.
 4. Remove the safety-clip and tag and close the circuit breaker 4QP.  On the ECAM DU:- the green left-wing transfer-valveindicator moves from the open to the closed position - the amber right-wing transfer-valve indicator moves from the intermediate
 to the closed (green) position - the fuel movement to the left-wing inner-cell stops.
 5. Open, safety and tag the circuit breaker 2QP.  On the ECAM display unit (DU):- the green left-wing transfer-valve indicator moves from the closed
 position to the open position - the green right-wing transfer-valve indicator moves from the closed
 position to the intermediate (amber) position - the left-wing outer-cell fuel content decreases and the left-wing inner-cell fuel content increases.
 6. Remove the safety-clip and tag and close the circuit breaker 2QP.  On the ECAM DU:- the green left-wing transfer-valveindicator moves from the open to the closed position 

R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-15-00Page 504 1201-299, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
7.
 Open, safety and tag the circuit breaker 1QP.

8.
 Remove the safety-clip and tag and close the circuit breaker 1QP.

 

R **ON A/C 401-499,
 Subtask 28-15-00-710-053-A
 -
the amber right-wing transfer-valve indicator moves from the intermediate to the closed (green) position

 -
the fuel movement to the left-wing inner-cell stops.


 