(3)
Energize the ECAM system (Ref. TASK 31-60-00-860-001).
(4)
On the ECAM control panel, push (in) the FUEL pushbutton switch (P/BSW).
(5)
On the ECAM System Display (SD), make sure that the FUEL page is shown.
(6)
On the ECAM SD FUEL page, make sure that the intercell transfer valves show closed.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-15-00Page 502 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
4. Procedure
_________
Subtask 28-15-00-865-051
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FUEL/XFR VALVE1/WING/R 2QP A11 49VU FUEL/XFR VALVE1/WING/L 1QP A10 121VU FUEL/XFR VALVE2/WING/R 4QP M23 121VU FUEL/XFR VALVE2/WING/L 3QP M22
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
Subtask 28-15-00-710-053
B. Operational Check of Individual Transfer Valves to Ensure Drive Shaft Rotates Valve to Open Position
NOTE : During the test the ECAM will show unwanted indications, which you
____
can ignore.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. Open, safety and tag the circuit On the ECAM display unit (DU):
breaker 3QP. - the green right-wing transfer-valve indicator moves from the closed position to the open position
-
the green left-wing transfer-valve indicator moves from the closed position to the intermediate (amber) position
-
the right-wing outer-cell fuel content decreases and the right-wing inner-cell fuel content increases.
2. Remove the safety-clip and tag On the ECAM DU: and close the circuit breaker - the green right-wing transfer-valve 3QP. indicator moves from the open to the
closed position
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-15-00Page 503 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- the amber left-wing transfer-valve indicator moves from the intermediate
to the closed (green) position - the fuel movement to the right-wing inner-cell stops.
3. Open, safety and tag the circuit breaker 4QP. On the ECAM display unit (DU):- the green left-wing transfer-valve indicator moves from the closed
position to the open position - the green right-wing transfer-valve indicator moves from the closed
position to the intermediate (amber) position - the left-wing outer-cell fuel content decreases and the left-wing inner-cell fuel content increases.
4. Remove the safety-clip and tag and close the circuit breaker 4QP. On the ECAM DU:- the green left-wing transfer-valveindicator moves from the open to the closed position - the amber right-wing transfer-valve indicator moves from the intermediate
to the closed (green) position - the fuel movement to the left-wing inner-cell stops.
5. Open, safety and tag the circuit breaker 2QP. On the ECAM display unit (DU):- the green left-wing transfer-valve indicator moves from the closed
position to the open position - the green right-wing transfer-valve indicator moves from the closed
position to the intermediate (amber) position - the left-wing outer-cell fuel content decreases and the left-wing inner-cell fuel content increases.
6. Remove the safety-clip and tag and close the circuit breaker 2QP. On the ECAM DU:- the green left-wing transfer-valveindicator moves from the open to the closed position
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-15-00Page 504 1201-299, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
7.
Open, safety and tag the circuit breaker 1QP.
8.
Remove the safety-clip and tag and close the circuit breaker 1QP.
R **ON A/C 401-499,
Subtask 28-15-00-710-053-A
-
the amber right-wing transfer-valve indicator moves from the intermediate to the closed (green) position
-
the fuel movement to the left-wing inner-cell stops.