ACTION RESULT -------------------------------------------------------------------------------
21. On the refuel/defuel control panel 800VU:
 -put the MODE SELECTOR switch to the DEFUEL/XFR position.
 22.
 On the panel 121VU:

 - open, safety and tag the circuit breaker 1QU.

 23.
 Close the refuel control panel door.

 24.
 On the applicable wing tank refuel valve(s) 7QU(8QU):

-push and hold in the manual plunger(s).

 25.
 On the panel 40VU:

-
push (in) the MODE SEL P/BSW

-
push (in) the XFEED P/BSW

-
push (in) the CTR TK PUMP 1 and PUMP 2 P/BSWs

 


-monitor the CTR TK display.
-
the applicable wing tank refuelvalve(s) open.

 On the panel 40VU:

 -
the MODE SEL P/BSW MAN light is on

 -
the LH and RH TK PUMP 1 and PUMP 2 P/BSW OFF lights are on

 -
the CTR TK PUMP 1 and PUMP 2 P/BSW OFF lights are on

 -
the XFEED P/BSW ON and OPEN lights are off.

On the panel 40VU:

-
the MODE SEL P/BSW MAN light goes off and the FAULT light comes on.

 On the ECAM upper DU:

 -
the message AUTO FEED FAULT comes on.

On the panel 40VU:

 -
the XFEED P/BSW ON and OPEN lights come on

-
the CTR TK PUMP 1 and PUMP 2 P/BSWOFF and FAULT lights go off

-
the MODE SEL P/BSW FAULT light stays on until sufficient fuel has been transferred (Center tank less than 250 kg (551.1555 lb)).


R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-21-00Page 519 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
On the ECAM upper DU: - the message AUTO FEED FAULT goes off.
 NOTE : When the low level sensor____ becomes dry, the center tank pumps will scavenge for 5 minutes before they are latched off.
 NOTE : When the center tank pumps____ pressure is low: - on the panel 40VU, the CTR TK PUMP 1 and PUMP 2 FAULT lights can come on
 - on the ECAM lower DU, the CTR TK PUMP 1 and PUMP 2 LO PR
 messages can come on. These warnings are not shown after the low level sensor
 becomes dry.
 26. On the MCDU:  On the MCDU:
 - push (in) the MCDU MENU key  - the MCDU MENU page is shown
 - push (in) the <CFDS line key  - the CFDS MENU page is shown
 - push (in) the <SYSTEM REPORT/TEST line key  - the SYSTEM REPORT/TEST MENU page isshown
 - push (in) the <FUEL line key  - the first page of the FUEL Main Menu is shown
 - push (in) the NEXT PAGE key  - the second page of the FUEL Main Menu is shown
 - push (in) the <INPUT PARAMETERS line key  - the FQIS INPUT PARAMETERS page isshown
 - push (in) the NEXT PAGE key  - the FQIS PROBE CAPACITIES page is shown
 - push (in) the NEXT PAGE key.  - the FQIS DISCRETE INPUTS page is shown. 

R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-21-00Page 520 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
27. On the MCDU:
-
identify and monitor the center tank LH low level sensor bit position indicator 7P

 -
identify and monitor the center tank RH low level sensor bit position indicator 4J


 -push (in) the NEXT PAGE key frequently until the sensor bit indicatiors change from 0 to 1.
 NOTE : Use of the NEXT PAGE key
____ frequently, allows the FQIS DISCRETE INPUTS page display to update.
 28.
 Make sure that the applicable center tank pump goes off automatically 5 minutes after its related sensor becomes dry.

29.
 On the applicable wing tank refuel valve(s) 7QU(8QU):

-release the manual plunger(s).

 30.
 On the center tank refuel valve 10QU:

 -push (in) and hold the manual plunger.

 31.
 On the panel 40VU:


-push (in) the LH and RH TK PUMP 1 and PUMP 2 P/BSWs.
On the MCDU:
-
the LH sensor bit indicator 7P isshown 0 (sensor wet)

-
the RH sensor bit indicator 4J isshown 0 (sensor wet)

-
the LH sensor bit indicator 7P and RHsensor bit indicator 4J change from 0(sensor wet) to 1 (sensor dry).


On the ECAM lower DU:
-the FUEL PAGE CTR TK PUMP 1 and PUMP2 symbols change from green in-line(pump on) to green cross-line (pump off)
 