-this indication is shown:
***** WARNING *****
***** TEST ACTIVE *****
-when the test has stopped this indication is shown: A NON-MONITORING TEST WAS PERFORMED DUE TO INSUFFICIENT STARTER AIR PRESSURE OR DUE TO A STARTER AIR VALVE FAILURE
-
the test results are shown
-
the TEST COMPLETE page is shown.
1EFF : 301-399, 1 28-21-00Page 411 1 1 May 01/04 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R R SYSTEM REPORT/TEST ENG page is shown
R R - push in the key adjacent to the FADEC 1B indication
R R - push in the key adjacent to the FADEC TEST indication
R R R R R - push in the key adjacent to the PUSH BUTTON TO START TEST> indication.
R R R R 8. On the panel 115VU: - make sure that the MODE switch (6KS) is in the NORM (center) position
R R R R R R R R R R R R R - put the MASTER 1 switch to the ON position.
R 9. On the MCDU:
R R R - push in the key adjacent to the DISPLAY NON-MONITORING TEST RESULTS indication
R R R - make sure that the indication J8, FRV (SOL2), ECU is not shown
-
the ENGINE 1 MAIN MENU is shown
-
the FADEC TEST ENGINE 1 CHANNEL B page is shown
-
this indication is shown: PUT THE MODE SELECTOR SWITCH TO <NORM> PLACE THE MASTER LEVER SWITCH TO <ON>
-
this indication is shown:
***** WARNING *****
***** TEST ACTIVE *****
-when the test has stopped this indication is shown: A NON-MONITORING TEST WAS PERFORMED DUE TO INSUFFICIENT STARTER AIR PRESSURE OR DUE TO A STARTER AIR VALVE FAILURE
-the test results are shown
1EFF : 301-399, 1 28-21-00Page 412 1 1 May 01/04 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R - push in the key adjacent to the
R RETURN indication.
R 10. On the panel 115VU, put the
R MASTER 1 switch to the OFF
R position.
R 11. On the MCDU:
R - push in the key adjacent to
R the RETURN indication until
R the SYSTEM REPORT/TEST ENG
R page is shown.
R
R 12. On the panel 50VU:
R - push in the ENG/FADEC GND PWR
R 1 P/BSW
R - make sure that the ENG/FADEC
R GND PWR 2 P/BSW is released
R out.
R
R 13. On the MCDU:
R - push in the key adjacent to
R the FADEC 2A indication
R - push in the key adjacent to
R the FADEC TEST indication
R - push in the key adjacent to
R the PUSH BUTTON TO START TEST>
R indication.
R
R
R 14. On the panel 115VU:
R - make sure that the MODE switch
R (6KS) is in the NORM (center)
R position
-
the TEST COMPLETE page is shown.
-
the OFF light of the ENG/FADEC GND PWR 1 P/BSW goes off
-
the ON light of the ENG/FADEC GND PWR 2 P/BSW is on.
-
the ENGINE 2 MAIN MENU is shown
-
the FADEC TEST ENGINE 2 CHANNEL A page is shown
-this indication is shown: PUT THE MODE SELECTOR SWITCH TO <NORM> PLACE THE MASTER LEVER SWITCH TO <ON>
1EFF : 301-399, 1 28-21-00Page 413 1 1 May 01/04 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R - put the MASTER 2 switch to the - this indication is shown:
R ON position.
R ***** WARNING *****
R ***** TEST ACTIVE *****
R
R - when the test has stopped this
R indication is shown:
R A NON-MONITORING TEST WAS
R PERFORMED DUE TO
R INSUFFICIENT STARTER
R AIR PRESSURE OR DUE TO
R A STARTER AIR VALVE
R FAILURE
R 15. On the MCDU:
R - push in the key adjacent to - the test results are shown
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油2(111)