R R R  6. On the panel 115VU, put the MASTER 1 switch to the OFF position. 
R R R  7. On the MCDU: - push in the key adjacent to the RETURN indication until the

-this indication is shown:
***** WARNING *****
***** TEST ACTIVE *****

-when the test has stopped this indication is shown: A NON-MONITORING TEST WAS PERFORMED DUE TO INSUFFICIENT STARTER AIR PRESSURE OR DUE TO A STARTER AIR VALVE FAILURE
-
the test results are shown

-
the TEST COMPLETE page is shown.


 1EFF : 301-399, 1 28-21-00Page 411 1 1 May 01/04 1 1 1CES 1


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R R  SYSTEM REPORT/TEST ENG page is shown 
R R  - push in the key adjacent to the FADEC 1B indication 
R R  - push in the key adjacent to the FADEC TEST indication 
R R R R R  - push in the key adjacent to the PUSH BUTTON TO START TEST> indication. 
R R R R  8. On the panel 115VU: - make sure that the MODE switch (6KS) is in the NORM (center) position 
R R R R R R R R R R R R R  - put the MASTER 1 switch to the ON position. 
R  9. On the MCDU: 
R R R  - push in the key adjacent to the DISPLAY NON-MONITORING TEST RESULTS indication 
R R R  - make sure that the indication J8, FRV (SOL2), ECU is not shown

-
the ENGINE 1 MAIN MENU is shown

-
the FADEC TEST ENGINE 1 CHANNEL B page is shown


-
this indication is shown: PUT THE MODE SELECTOR SWITCH TO <NORM> PLACE THE MASTER LEVER SWITCH TO <ON>

-
this indication is shown:


***** WARNING *****
***** TEST ACTIVE *****

-when the test has stopped this indication is shown: A NON-MONITORING TEST WAS PERFORMED DUE TO INSUFFICIENT STARTER AIR PRESSURE OR DUE TO A STARTER AIR VALVE FAILURE
-the test results are shown
 1EFF : 301-399, 1 28-21-00Page 412 1 1 May 01/04 1 1 1CES 1


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R  - push in the key adjacent to the 
R  RETURN indication. 
R  10. On the panel 115VU, put the 
R  MASTER 1 switch to the OFF 
R  position. 
R  11. On the MCDU: 
R  - push in the key adjacent to 
R  the RETURN indication until 
R  the SYSTEM REPORT/TEST ENG 
R  page is shown. 

R  12. On the panel 50VU: 
R  - push in the ENG/FADEC GND PWR 
R  1 P/BSW 
R  - make sure that the ENG/FADEC 
R  GND PWR 2 P/BSW is released 
R  out. 

R  13. On the MCDU: 
R  - push in the key adjacent to 
R  the FADEC 2A indication 
R  - push in the key adjacent to 
R  the FADEC TEST indication 
R  - push in the key adjacent to 
R  the PUSH BUTTON TO START TEST> 
R  indication. 


R  14. On the panel 115VU: 
R  - make sure that the MODE switch 
R  (6KS) is in the NORM (center) 
R  position

-
the TEST COMPLETE page is shown.


-
the OFF light of the ENG/FADEC GND PWR 1 P/BSW goes off

-
the ON light of the ENG/FADEC GND PWR 2 P/BSW is on.

-
the ENGINE 2 MAIN MENU is shown

-
the FADEC TEST ENGINE 2 CHANNEL A page is shown


-this indication is shown: PUT THE MODE SELECTOR SWITCH TO <NORM> PLACE THE MASTER LEVER SWITCH TO <ON>
1EFF : 301-399, 1 28-21-00Page 413 1 1 May 01/04 1 1 1CES 1


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R  - put the MASTER 2 switch to the  - this indication is shown: 
R  ON position. 
R  ***** WARNING ***** 
R  ***** TEST ACTIVE ***** 

R  - when the test has stopped this 
R  indication is shown: 
R  A NON-MONITORING TEST WAS 
R  PERFORMED DUE TO 
R  INSUFFICIENT STARTER 
R  AIR PRESSURE OR DUE TO 
R  A STARTER AIR VALVE 
R  FAILURE 
R  15. On the MCDU: 
R  - push in the key adjacent to  - the test results are shown 
 