• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-22 06:49来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

-remove the safety clip and the tag and close the circuit breaker 31QA.
 5. On the panel 40VU:
-release (out) the CTR TK PUMP 1 P/BSW.
On the panel 40VU:
-the CTR TK PUMP 1 and PUMP 2 P/BSWOFF lights are on.
The CTR TK PUMP 1 supply and indicationcircuits are energized.
On the panel 40VU:
-
the CTR TK PUMP 1 P/BSW OFF lightgoes off

 -
the CTR TK PUMP 1 P/BSW FAULT light comes on.

On the panel 40VU:

-
the CTR TK PUMP 1 P/BSW FAULT lightgoes off.

 On the ECAM lower DU:

 -
the CTR TK PUMP 1 shows green in-line (pump on).

On the ECAM lower DU:

-
the CTR TK PUMP 1 shows ambercross-line (pump off).


 On the panel 40VU:
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-21-00Page 513 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
- the CTR TK PUMP 1 P/BSW OFF light
 comes on.
 6. On the panel 121VU:
 - open, safety and tag the  - the CTR TK PUMP 1 supply and
 circuit breakers 29QA and 32QA  indication circuits are isolated
 - remove the safety clip and the  - the CTR TK PUMP 2 supply circuit is
 tag and close the circuit  energized.
 breaker 30QA.
 7. On the panel 40VU:  On the panel 40VU:
 - push (in) the CTR TK PUMP 2  - the CTR TK PUMP 2 P/BSW OFF light
 P/BSW.  goes off
 - the CTR TK PUMP 2 P/BSW FAULT light
 comes on.
 8. On the panel 121VU:  On the panel 40VU:
 - remove the safety clip and the  - the CTR TK PUMP 2 P/BSW FAULT light
 tag and close the circuit  goes off.
 breaker 32QA.
 On the ECAM lower DU:
 - the CTR TK PUMP 2 shows green in-line
 (pump on).
 9. On the panel 40VU:  On the ECAM lower DU:
 - release (out) the CTR TK PUMP 2  - the CTR TK PUMP 2 shows amber
 P/BSW.  cross-line (pump off).
 On the panel 40VU:
 - the CTR TK PUMP 2 P/BSW OFF light
 comes on.
 10. On the panel 121VU:
 - open, safety and tag the  - the CTR TK PUMP 1 and PUMP 2 control,
 circuit breakers 30QA, 31QA  supply and indication circuits are
 and 32QA.  isolated. 

R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-21-00Page 514 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1 Subtask 28-21-00-720-051-A


 B. Functional Test of the Center-Tank Fuel Control (Auto Mode)
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the panel 40VU:
-push (in) the MODE SEL P/BSW.
2.
 Refuel each wing tank to 5500 kg (12125.4210 lb) (Ref. TASK 12-11-28-650-004).

 3.
 After refueling, on the panel 800VU:

-make sure that the MODE SELECT switch is in the OFF position.

 4.
 On the panel 40VU:

-push (in) the CTR TK PUMP 1 and PUMP 2 P/BSWs.

5.
 On the panel 121VU:

-
remove the safety clip and the tag and close the circuit breakers 31QA and 32QA

 -
remove the safety clip and the tag and close the circuit breaker 47QA.

 


On the panel 40VU:
-
the MODE SEL P/BSW MAN light goes off

 -
the MODE SEL P/BSW FAULT light comes on.

 On the ECAM upper DU:

 -
the message AUTO FEED FAULT comes on.


On the panel 40VU:
-
the MODE SEL P/BSW FAULT light goesoff.

 On the ECAM upper DU:

 -
the message AUTO FEED FAULT goes off.

On the panel 40VU:

-
the CTR TK PUMP 1 and PUMP 2 P/BSWOFF lights go off.

On the panel 40VU:

-
the CTR TK PUMP 1 and PUMP 2 P/BSWFAULT lights come on.


 On the ECAM lower DU:
 -CTR TK PUMP 1 LO PR and CTR TK PUMP 2 LO PR come on.
On the panel 40VU:
-the CTR TK PUMP 1 and PUMP 2 P/BSWFAULT lights go off.
 On the ECAM lower DU:
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-21-00Page 515 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
6.
 On the panels 49VU and 121VU:

- open, safety and tag the circuit breakers 5CV and 7CV.


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油2(117)