• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 23:44来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Necessary Altitude Flow  ALTITUDE - FEET X 1000 
5  10  15  20  25  30 
32`F) Liters/Minute in Standard (760 mm Hg,  Necessary ground level (760 mm Hg) flow value in standard liters/minute 
3.0 8.0 7.0 4.0 2.7 2.5 2.0 0.5  9.58 8.40 4.83 3.72 3.37 3.07 2.51 0.74  9.71 8.52 4.98 3.85 3.48 3.21 2.65 0.86  9.92 8.71 5.10 3.97 3.58 3.30 2.72 0.91  8.81 5.21 4.08 3.65 3.40 2.80 0.96 10.02  10.12 8.91 5.30 4.14 3.72 3.44 2.84 1.00 10.25 9.02 5.38 4.22 3.78 3.47 2.89 1.08 

Outlet Assembly Ground Level Flow Value for Portable Oxygen Cylinder
Figure 502

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-31-00
 ALL  ú ú 01 Page 503 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 PORTABLE OXYGEN EQUIPMENT - INSPECTION/CHECK
____________________________________________
 1. General
________
 A. This procedure contains one task:
 (1)  The portable oxygen cylinder inspection/check.
 TASK 35-31-00-206-001
 2. Portable Oxygen Cylinder Check
______________________________
 A. Consumable Materials
 (1) G00091 Oxygen System Leak Detection Compound, (Ref 20-30-51)
 B. Access
 (1)  Location Zone
 100 Upper Half of the Fuselage

 C. Do a Check of the Portable Oxygen Cylinder
 S 216-016
 (1)  Make sure the oxygen cylinder is in compliance with local regulatory requirements currently in effect for hydrostatic test.
 NOTE: The last hydrostatic test date will be stamped on the neck of
____
 the oxygen cylinder.

 S 216-002
 (2)  
Do a check of the pressure on the pressure gage.

 S 216-003

 (3)  
Make sure the oxygen cylinder gage pressure is not more than 1850 psi at 70°F (21°C).


 NOTE: See Fig. 601 for equivalent portable oxygen cylinder
____ pressures for temperatures other than 70°F (21°C).
 S 966-004
 (4)  
Replace the portable oxygen cylinder, if the gage pressure is below the minimum guideline set for the airline or regulatory authority.

 S 866-005

 (5)  
Turn the knob on the ON-OFF valve a minimum of one-half turn and open the ON-OFF valve.

 S 796-006

 (6)  
Apply the leak detection compound to all the fittings and connections.


 NOTE: Bubbles will show there are leaks that you must repair.
____
 S 436-007
 (7)  Tighten the fitting connections to repair the leakage.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-31-00
 ALL  ú ú 02 Page 601 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 866-008
 (8)  If the leakage continues, send the portable oxygen cylinder to an approved overhaul shop.
 NOTE: Leakage is not permitted.
____
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-31-00
 ALL  ú ú 02 Page 602 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
TEMPERATURE - DEGREES FAHRENHEIT
-40 -22 -4 +14 +32+68 +86 +104 +122 +140
+50
2000

1900 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700
PORTABLE OXYGEN CYLINDER PRESSURE - PSI


MAXIMUM ALLOWABLE PRESSURE FOR FULLY SERVICED PORTABLE OXYGEN CYLINDER
Potable Oxygen Cylinder - Pressure/Temperature Correction Chart Figure 601
F42920
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 氧气 OXYGEN(65)