(2)
Vacuum gage.
(3)
Altitude pressure switch adapter kit - P/N JAK136 (Consolidated Controls Corp.)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-22-00
ALL ú ú 01 Page 101 ú Jul 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
G. Prepare for Trouble Shooting
(1)
Supply electrical power (Ref 24-22-00/201).
(2)
On each service unit, deploy test stop button (Fig. 101):
(a)
Use a a small flat tool, carefully push the test stop button down.
(b)
Hold the button and pull down to the limit of travel.
(c)
Turn the button counterclockwise 90° to the test position.
(3)
Make sure that these circuit breakers are closed:
(a)
On the indicator master dim bus, P6 panel: 1) BAT 2) NO. 1 DC 3) NO. 2 DC 4) SECT 1 5) SECT 2 6) SECT 3 7) SECT 4 8) SECT 5 9) SECT 6 10) DIM & TEST
(b)
MASTER CAUTION
1) AIR COND
2) ANTI - ICE
3) FUEL
4) ANNUNCIATOR NO. 1
5) ANNUNCIATOR BAT
(c)
P18 Panel - OXYGEN SYSTEM
1) IND
2) MANUAL CONTROL
3) PASS R
4) PASS L
(4)
On the P7 lightshield, push the MASTER CAUTION light.
(5)
Make sure the MASTER CAUTION and the OVERHEAD annunciator lights go off.
2. AIRPLANES WITH P/N 214C40-75 ALTITUDE PRESSURE SWITCH AND PRE-SB 35-1025; Connect Adapter Kit to S813 Altitude Pressure Switch____________________________________________________
A. Procedure
(1) Get access to the altitude pressure switch, S813 (AMM 35-22-41/401).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-22-00
ALL ú ú 01 Page 102 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(CLOSED POSITION)
LATCH ACTUATOR PLUNGER IN THE RESET POSITION BEFORE YOU CLOSE THE MASK BOX DOOR
Mask Box Door Operation Figure 101
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-22-00
ALL ú ú 01 Page 103 ú Jul 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(2) (3) (4) (5) Clean and dry flat bottom surface of switch with a lint-free cloth.Install the O-ring in the O-ring groove on the adapter fitting.Use the three screws to attach the fitting to the bottom of the switch.Safety the screws per MS33540 with lockwire.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:737-300 400 500 AMM 飞机维护手册 氧气 OXYGEN(36)