35-31-00
ALL ú ú 03 Page 1 ú Jul 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
TWO OXYGEN CYLINDERS
IN THE STORAGE UNIT
ON THE WINDSCREEN
1
TWO OXYGEN CYLINDERS IN THE STORAGE BIN
TWO OXYGEN CYLINDERS ON THE FORWARD FACE OF THE LAVATORY
____ ALL CYLINDERS HAVE A CAPACITY
NOTE: OF 4.25 OR 11.0 CUBIC FEET.
1
AIRPLANES WITH A FORWARD
LEFT SIDE WINDSCREEN
ALL EXCEPT
Portable Oxygen Equipment Figure 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-31-00
ALL ú ú 17 Page 2 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
Portable Oxygen Equipment Schematic
Figure 2
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-31-00
ALL ú ú 01 Page 3 ú Jun 25/84
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
PORTABLE OXYGEN EQUIPMENT - ADJUSTMENT/TEST
______________________________________________
1. General________
A. This procedure contains two tasks:
(1)
The Portable Oxygen Cylinder Adjustment
(2)
The Portable Oxygen Cylinder Test
TASK 35-31-00-705-001
2. Portable Oxygen Cylinder Adjustment___________________________________
A. General
(1) Do not adjust a portable oxygen cylinder in the field. Send the portable oxygen cylinder to an approved overhaul shop if it does not operate correctly.
TASK 35-31-00-705-002
3. Portable Oxygen Cylinder Test_____________________________
A. Access
(1) Location Zone
100 Upper Half of the Fuselage
B. Procedure
S 865-003
(1)
Turn the knob on the ON-OFF valve a minimum of one-half turn and open the ON-OFF valve.
S 865-004
(2)
Install the mask hose fitting in all of the outlet assemblies.
S 215-005
(3)
Do a check of the flow for each outlet assembly with a flowmeter.
NOTE: All of the outlet assemblies have a code for the flow and
____ altitude value. The code is shown by two numbers separated by a dash. The first number shows the flow in liters per minute, and the second shows the altitude. If the outlet assembly does not have a code, or you can not read the code, you can find the flow and altitude value in the basic equipment part number. (See figure 501.) To get the necessary flow value at the applicable altitude, make sure the flow value for the ground level outlet assembly is in the range shown in Fig. 502.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-31-00
ALL ú ú 01 Page 501 ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
5500-A1A-C5A
Outlet Assembly Flow and Altitude Value from the Basic Cylinder Part Number
for Portable Oxygen Cylinder
Figure 501
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
35-31-00
ALL ú
ú 01 Page 502
ú Nov 15/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 氧气 OXYGEN(64)