• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 23:44来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

LANYARD 
(2 LOCATIONS) 
FORWARD ATTENDANT SERVICE UNIT 
(AFT ASU IS EQUIVALENT) 
OXYGEN MASK 
(2 LOCATIONS) 
OXYGEN 
SUPPLY HOSE 
(2 LOCATIONS) 
OXYGEN 
MASKS 
RESERVOIR 
BAG 
(2 LOCATIONS) 

OXYGEN BOX A
RELEASE CABLE
MASK PACKING B Attendent Servive Unit (ASU) Oxygen Mask Installation Figure 403
H21821
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-22-31
 ALL  ú ú 01 Page 411 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
LAVATORY
SERVICE UNIT (LSU)

SEE A

ALTERNATE
LAVATORY SERVICE UNIT

SEE B RELEASE CABLE OXYGEN BOX
FWD
FORWARD LAVATORY (AFT LAVATORY IS EQUIVALENT)
LANYARD
(2 LOCATIONS) FORWARD LSU
OXYGEN MASK
(2 LOCATIONS)

FWD
RESERVOIR BAG
(2 LOCATIONS)

STREAMER (2 LOCATIONS)
LAVATORY SERVICE UNIT (FORWARD LAVATORY)
A
Lavatory Service Unit (LSU) Oxygen Mask Installation
Figure 404 (Sheet 1)

H21222
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-22-31
 ALL  ú ú 01 Page 412 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
MASK PACKING
SEE C
LANYARD
(2 LOCATIONS)

OXYGEN MASK
(2 LOCATIONS)

OXYGEN
SUPPLY HOSE
(2 LOCATIONS)

MASK BAG (2 LOCATIONS)
STREAMER
OXYGEN
 MASKS

(2 LOCATIONS)
PULL

LAVATORY SERVICE UNIT (ALTERNATE LSU) STREAMER (2 LOCATIONS)
B
RELEASE CABLE
MASK PACKING
C

Lavatory Service Unit (LSU) Oxygen Mask Installation
Figure 404 (Sheet 2)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-22-31
 ALL  ú ú 01 Page 413 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
H21230
A 737-300/400/500MAINTENANCE MANUAL
 S 424-032
 (2)  If you remove the oxygen generator, install a generator that did not fire (Ref 35-22-11/401).
 (a)  Do not activate the generator.
 E. Procedure - Install the Oxygen Masks
 S 434-033
 (1)  
Connect the mask tubing on the generator outlets (Fig. 403).

 S 434-034

 (2)  
Push the tubing fully on the outlets.

 S 434-035

 (3)
On the forward attendant's oxygen masks, do the steps that follow:

 (a)  
Put the two mask tubes in the clamp.

 (b)  
Put the clamp in its position and loosely install the screw that attaches the clamp to the mask box wall.

 (c)  
Make sure the mask tubes have a smooth bend radius and that the tubes have no kinks or sharp bends.

 (d)  
Tighten the screw that attaches the clamp to the mask box wall.

 

 

Oxygen Box Door Manual Opening
Figure 405

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 35-22-31
 ALL  ú ú 01 Page 414 ú Mar 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
H21264
A 737-300/400/500MAINTENANCE MANUAL
 (4)  S 434-057On all masks (this does not include the forward attendant's masks), do the steps that follow: (a) Put the two mask tubes in the clamp. (b) Make sure that each mask tube has a smooth bend radius and has no kinks or sharp bends. (c) Use a strap installation tool to install a tiedown strap through the slot in the clamp.
 (5)  S 834-037Put the release pin through the two mask lanyard rings.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 氧气 OXYGEN(59)