-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B221
--Feb 01/05R ---CES -
Drift of the Pressure Transducer on the Engine 2
1. Possible Causes_______________
-
XDCR-BLEED REGULATED PRESS, ENG 2 (8HA2)
-
XDCR-BLEED TRANSFER PRESS, ENG 2 (7HA2)
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 36-11-00-710-002 Operational Test to Read the CLASS III FAULTS
AMM 36-11-15-000-001 Removal of the Bleed Transferred Pressure Transducer (7HA1,7HA2)
AMM 36-11-15-400-001 Installation of the Bleed Transferred Pressure Transducer (7HA1,7HA2)
AMM 36-11-16-000-001 Removal of the Bleed Regulated Pressure Transducer (8HA1,8HA2)
AMM 36-11-16-400-001 Installation of the Bleed Regulated Pressure Transducer (8HA1,8HA2)
3. Fault Confirmation__________________
A. Test
(1) Not Applicable
4. Fault Isolation_______________
A. Do the operational test to read the class III faults of the BMC (Ref. AMM TASK 36-11-00-710-002)
(1)
If the operational test gives the maintenance message:
DRIFT REG-PRESS XDCR 8HA2
-replace the XDCR-BLEED REGULATED PRESS, ENG 2 (8HA2) (Ref. AMM TASK 36-11-16-000-001) and (Ref. AMM TASK 36-11-16-400-001).
(2)
If the operational test gives the maintenance message:
DRIFT TRANSF-PRESS XDCR 7HA2
-replace the XDCR-BLEED TRANSFER PRESS, ENG 2 (7HA2) (Ref. AMM TASK 36-11-15-000-001) and (Ref. AMM TASK 36-11-15-400-001).
1
-EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B222
--Feb 01/05R ---CES -
(3) If the operational test does not gives the above maintenance message:
-replace the XDCR-BLEED REGULATED PRESS, ENG 2 (8HA2) (Ref. AMM TASK 36-11-16-000-001) and (Ref. AMM TASK 36-11-16-400-001).
(a) If the fault continues:
-replace the XDCR-BLEED TRANSFER PRESS, ENG 2 (7HA2) (Ref. AMM TASK 36-11-15-000-001) and (Ref. AMM TASK 36-11-15-400-001).
1
-EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B223
--Feb 01/05R ---CES -
Failure of the Bleed Pressure Regulator Valve Control Solenoid or its Wiring
1. Possible Causes
_______________
-SOLENOID-BLEED PRESS REG V CTL, ENG 1 (10HA1)
-P/BSW-ENG 1 BLEED (4HA1)
-SOLENOID-BLEED PRESS REG V CTL, ENG 2 (10HA2)
-P/BSW-ENG 2 BLEED (4HA2)
-wiring
-
C/B-AIR BLEED/ENG 1/CTL (3HA1)
-
C/B-AIR BLEED/ENG 2/CTL (3HA2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R 24-00-00-810-803 Circuit Breaker Tripped and/or C/B TRIPPED Warning AMM 36-11-55-000-001 Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid (10HA1,10HA2) AMM 36-11-55-400-001 Installation of the Bleed-Pressure-Regulator Valve
Control-Solenoid (10HA1,10HA2)
ASM 36-11/01
ASM 36-11/02
3. Fault Confirmation
__________________
A. Test.
(1) Not applicable.
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/ENG 1/CTL 3HA1 D12 122VU AIR BLEED/ENG 2/CTL 3HA2 Z23
1 -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B224
--May 01/05 ---CES -
B. If the fault symptom is identified by the status message ONE PACK ONLY IF WAI ON: - on the overhead circuit breaker panel 49VU, do a check of the status of
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(93)