 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001),
 -refer to Para. 4.B.
 * if the impedance is more than 3 KOhms:
 -replace the OVHT SENS ELEMENT (17HF) (Ref. AMM TASK 36-22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.B.
 1
R -EFF : 001-049, 051-099, 101-149, 151-199,

-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 289
 -201-299, 401-499, -Aug 01/05 ---CES -

 b
_

If the impedance is more than 3 KOhms:
 -connect the connector between the sensing elements 17HF and 18HF
 -disconnect the connector between the sensing element 19HF and the cable 20HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI) . if the impedance is less than 3 KOhms:
 -disconnect the connector between the sensing elements 18HF and 19HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the OVHT SENS ELEMENT (18HF) (Ref. AMM TASK 36-22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.B.
 * if the impedance is more than 3 KOhms:
 -replace the OVHT SENS ELEMENT (19HF) (Ref. AMM TASK 36-22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.B.
 . if the impedance is more than 3 KOhms

 -replace the CABLE ASSY (20HF) (Ref. AMM TASK 36-22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)
 -connect all the cables or connectors disconnected
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI)
 * if the impedance is less than 3 KOhms:
 -do a check and repair the wiring between the pin AA/8B of the BMC1 (1HA1) and the cable 20HF
 -connect all the cables or connector disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.B.
 * if the impedance is more than 3 KOhms:
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.B.
 1
R -EFF : 001-049, 051-099, 101-149, 151-199,

-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 290
 -201-299, 401-499, -Aug 01/05 ---CES -


R  **ON A/C 301-399, 
R  A. If the test gives the maintenance message: 
R  APU LOOP 
R  - remove the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) 
R  - on the shelf 95VU, connect the LOOP CONTROLLER (9240SI) between the 
R  connector 1HA1-AA/7B and the ground (Ref. ASM 36-22/01) 
R  - do a check of the impedance read on the LOOP CONTROLLER (9240SI). 
R  (1) If the impedance is more than 3 KOhms: 
R  - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector 
R  - replace the BMC-1 (1HA1) which is removed (Ref. AMM TASK 36-11-34-
R  000-001) and (Ref. AMM TASK 36-11-34-400-001). 
R  - refer to Para. 4.B. 
R  (2) If the impedance is less than 3 KOhms: 
R  - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector 
R  - do a visual inspection of the sensing elements and cables on the 
R  APU loop. 
R  (a) If a sensing element or cable is damaged: 
R  - replace the sensing element or cable (Ref. AMM TASK 36-22-17-
R  000-001) and (Ref. AMM TASK 36-22-17-400-001) 
R  - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector 
R  - install the BMC1 (Ref. AMM TASK 36-11-34-400-001) 
R  - refer to Para. 4.B. 
R  (b) If no sensing element is damaged: 
R  - disconnect the connector between the sensing elements 15HF and 
R  16HF 
R  - connect the LOOP CONTROLLER (9240SI) between the connector 
 