 --May 01/04R ---CES -

 2
_

_
 -disconnect the connector between the sensing element 39HF

 and 40HF
 -connect the connector between the sensing elements 38HF and 39HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI). . if the impedance is less than 3 KOhms:
 -replace the SNSG ELEM-OVHT, R WING LOOP A (39HF) (Ref. AMM TASK 36-22-16-000-005) and (Ref. AMM TASK 36-22-16-400-005)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 . if the impedance is more than 3 KOhms:

 -disconnect the connector between the cables 40HF and 41HF
 -connect the connector between the cable 40HF and the sensing element 39HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI)
 * if the impedance is less than 3 KOhms:
 -replace the CABLE-CONNECTING, R WING LOOP A (40HF) (Ref. AMM TASK 36-22-16-000-003) and (Ref. AMM TASK 36-22-16-400-003)
 -connect all the cables or connectors disconnected
 -disconnet the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the CABLE-CONNECTING, R WING LOOP A (41HF) (Ref. AMM TASK 36-22-16-000-007) and (Ref. AMM TASK 36-22-16-400-007)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector.
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
If the impedance is more than 3 KOhms:
 -disconnect the connector between the sensing elements 44HF and 45HF
 -connect the connector between the sensing element 42HF and the cable 41HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 274
 --May 01/04R ---CES -


 a
_
 b
_
If the impedance is less than 3 KOhms:
 -disconnect the connector between the sensing elements 42HF and 43HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI) . if the impedance is less than 3 KOhms:
 -replace the SNSG ELEM-OVHT, R WING LOOP A (42HF) (Ref. AMM TASK 36-22-16-000-004) and (Ref. AMM TASK 36-22-16-400-004)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001),
 -refer to Para. 4.C.
 . if the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing elements 43HF and 44HF
 -connect the connector between the sensing elements 42HF and 43HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the SNSG ELEM-OVHT, R WING LOOP A (43HF) (Ref. AMM TASK 36-22-16-000-005) and (Ref. AMM TASK 36-22-16-400-005)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the SNSG ELEM-OVHT, R WING LOOP A (44HF) (Ref. AMM TASK 36-22-16-000-006) and (Ref. AMM TASK 36-22-16-400-007)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
If the impedance is more than 3 KOhms:
 -disconnect the connector between the sensing elements 74HF and 47HF
 -connect the connector between the sensing elements 44HF and 45HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI) . if the impedance is less than 3 KOhms:
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 275
 --May 01/04R ---CES -


 -disconnect the connector between the sensing elements
 45HF and 74HF

 -do a check of the impedance read on the LOOP CONTROLLER
 (9240SI).

 * if the impedance is less than 3 KOhms:

 -replace the SNSG ELEM-OVHT, R WING LOOP A (45HF) (Ref.
 AMM TASK 36-22-16-000-001) and (Ref. AMM TASK 36-22-16-400-001)
 