• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 23:25来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 267
 --May 01/04R ---CES -

 b
_

If the impedance is more than 3 KOhms:
 -disconnect the connector between the sensing elements 49HF and 83HF
 -connect the connector between the cables 52HF and 51HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI). . if the impedance is less than 3 KOhms:
 -disconnect the connector between the cable 51HF and the
 sensing element 50HF

 -do a check of the impedance read on the LOOP CONTROLLER
 (9240SI).

 * if the impedance is less than 3 KOhms:

 -replace the CABLE-CONNECTING, L WING LOOP B (51HF)
 (Ref. AMM TASK 36-22-16-000-003) and (Ref. AMM TASK 36-22-16-400-003)

 -connect all the cables or connectors disconnected

 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2
 connector

 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)

 -refer to Para. 4.C.

 * if the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing elements
 50HF and 49HF

 -connect the connector between the cable 51HF and the
 sensing element 50HF

 -do a check of the impedance read on the LOOP CONTROLLER
 (9240SI).
 ** if the impedance is less than 3 KOhms:

 -replace the SNSG ELEM-OVHT, L WING LOOP B (50HF) (Ref.
 AMM TASK 36-22-16-000-005) and (Ref. AMM TASK 36-22-16-400-005)

 -connect all the cables or connectors disconnected

 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2
 connector

 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)

 -refer to Para. 4.C.
 ** if the impedance is more than 3 KOhms:

 -replace the SNSG ELEM-OVHT, L WING LOOP B (49HF) (Ref. AMM TASK 36-22-16-000-006) and (Ref. AMM TASK 36-22-16-400-007)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 . If the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing element 83HF and the cable 77HF
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 268
 --May 01/04R ---CES -


 -connect the connector between the sensing elements 49HF
 and 83HF

 -do a check of the impedance read on the LOOP CONTROLLER
 (9240SI).

 * if the impedance is less than 3 KOhms:

 -replace the SNSG ELEM-OVHT, L WING LOOP B (83HF) (Ref.
 AMM TASK 36-22-16-000-001) and (Ref. AMM TASK 36-22-16-400-001)

 -connect all the cables or connectors disconnected

 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2
 connector

 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)

 -refer to Para. 4.C.

 * if the impedance is more than 3 KOhms:

 -replace the CABLE-CONNECTING, L WING LOOP B (77HF)
 (Ref. AMM TASK 36-22-16-000-002) and (Ref. AMM TASK 36-22-16-400-002)

 -connect all the cables or connectors disconnected

 -
do a check of the impedance read on the LOOP CONTROLLER
 (9240SI).
 ** if the impedance is less than 3 KOhms:


 -
do a check and repair the wiring between the pin AA/4D
 of the BMC2 (1HA2) and the cable 77HF

 

 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2
 connector

 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)

 -refer to Para. 4.C.
 ** if the impedance is more than 3 KOhms:

 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2
 connector

 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)

 -refer to Para. 4.C.

 B. If the test gives the TEST OK message:
 -
do a functional test of the bleed air supply system (Ref. AMM TASK 36-11-00-720-004)

 -
do the leak check on the bleed air ducts (Ref. AMM TASK 36-22-00-790-001).


 -repair the duct which causes the leak.
 C. Do the test given in para. 3.
 1
 -EFF : ALL
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(137)