 If the test gives that the APU supplies
 . no bleed-air pressure
 or
 . low or fluctuating bleed-air pressure:


 -do the related trouble shooting task (Ref. TASK 49-00-00-810-937).

 (3)
 If the fault continues:

 -replace the APU BLEED P/BSW (5HV) on panel 30VU.

 (4)
 If the fault continues:

 -do a check and repair if necessary the wiring between: the BMC-1, BMC-2 connector AB/6A and the ECB (ELECTRONIC CONTROL BOX) (59KD) connector AB/D6 (Ref. ASM 36-12/00).

 (5)
 If the fault continues:


 -do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/14C and the APU BLEED P/BSW (5HV) connector A/B1 (Ref. ASM 36-12/00), the APU BLEED P/BSW (5HV) connector A/B3 and GND (Ref. ASM 36-12/00).
 1
R -EFF : 051-099, 106-149, 211-299, 301-399,

-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 208
 -401-499, -Aug 01/05 ---CES -


 (6)
 If the fault continues:

 -do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/15C and the APU LOAD-CONTROL VALVE connector P/33 (Ref. ASM 36-12/00), the APU LOAD-CONTROL VALVE connector P4 and GND (Ref. ASM 36-12/00).

 (7)
 If the fault continues:

 -replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).

 (8)
 If the fault continues:


 -replace the BMC-1 (1HA1) or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 **ON A/C ALL
 C. Do the test as given in para. 3 to make sure that the operation is
 correct.

 5. Close-up
________
 A. Put the aircraft back to the serviceable condition.
 (1)
 On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.

 (2)
 De-energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-862-002).

 

 1
 -EFF : ALL


-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 209
 --May 01/05R ---CES -

 

 Fault of the Crossbleed Valve Position Control
 1. Possible Causes
_______________

 -VALVE-X BLEED (6HV)
 -BMC-1 (1HA1)
 -BMC-2 (1HA2)
 -wiring

 -X-BLEED-VALVE AUTO CTL RELAY (4HV)
 -CROSSBLEED-VALVE SELECTOR SWITCH (3HV)
 -X-BLEED-VALVE AUTOMATIC-CONTROL RELAY (4HV)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
 AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
 AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
 AMM 36-12-52-000-001 Removal of the Crossbleed Valve (6HV)
 AMM 36-12-52-400-001 Installation of the Crossbleed Valve (6HV)

R  AMM 49-00-00-860-003 APU Start by External Power (GTCP 36-300)
R  AMM 49-00-00-860-004 APU Shutdown by External Power (GTCP 36-300) AMM 49-00-00-860-005 APU Start by External Power (APS 3200) AMM 49-00-00-860-006 APU Shutdown by External Power (APS 3200) AMM 49-00-00-860-008 APU Start by External Power (131-9(A)) AMM 49-00-00-860-009 APU Shutdown by External Power (131-9(A)) ASM 36-12/01
 3. Fault Confirmation
__________________

R  **ON A/C 001-049, 101-105, 151-199, 201-210,
 A. Test

 (1)
 Start the APU (Ref. AMM TASK 49-00-00-860-008).

 (2)
 On the AIR COND panel 30VU:

 (a)
 Make sure that:

 -
the APU BLEED p/bsw ON legend shows on.

 -
the OFF legend on the PACK 1 and the PACK 2 p/bsw shows off.

 

 (b)
 Set the X BLEED selector to the OPEN position.

 


 1 -EFF : ALL

-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 210
 --May 01/05 ---CES -


 (3) Do the operational test of both BMCs (Ref. AMM TASK 36-11-00-740-001).
 (4) Stop the APU (Ref. AMM TASK 49-00-00-860-009).
 **ON A/C 051-099,

 A. Test
 (1)
 Start the APU (Ref. AMM TASK 49-00-00-860-003).

 (2)
 On the AIR COND panel 30VU:

 (a)
 Make sure that:
 
中国航空网 www.aero.cn