(2)
If the test gives that the APU supplies
. no bleed-air pressure
or
. low or fluctuating bleed-air pressure:
-do the related trouble shooting task (Ref. TASK 49-00-00-810-937).
(3)
If the fault continues:
-replace the APU BLEED P/BSW (5HV) on panel 30VU.
(4)
If the fault continues:
-do a check and repair if necessary the wiring between: the BMC-1, BMC-2 connector AB/6A and the ECB (ELECTRONIC CONTROL BOX) (59KD) connector AB/D6 (Ref. ASM 36-12/00).
(5)
If the fault continues:
-do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/14C and the APU BLEED P/BSW (5HV) connector A/B1 (Ref. ASM 36-12/00), the APU BLEED P/BSW (5HV) connector A/B3 and GND (Ref. ASM 36-12/00).
1
R -EFF : 051-099, 106-149, 211-299, 301-399,
-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 208
-401-499, -Aug 01/05 ---CES -
(6)
If the fault continues:
-do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/15C and the APU LOAD-CONTROL VALVE connector P/33 (Ref. ASM 36-12/00), the APU LOAD-CONTROL VALVE connector P4 and GND (Ref. ASM 36-12/00).
(7)
If the fault continues:
-replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).
(8)
If the fault continues:
-replace the BMC-1 (1HA1) or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
**ON A/C ALL
C. Do the test as given in para. 3 to make sure that the operation is
correct.
5. Close-up
________
A. Put the aircraft back to the serviceable condition.
(1)
On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
(2)
De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
1
-EFF : ALL
-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 209
--May 01/05R ---CES -
Fault of the Crossbleed Valve Position Control
1. Possible Causes
_______________
-VALVE-X BLEED (6HV)
-BMC-1 (1HA1)
-BMC-2 (1HA2)
-wiring
-X-BLEED-VALVE AUTO CTL RELAY (4HV)
-CROSSBLEED-VALVE SELECTOR SWITCH (3HV)
-X-BLEED-VALVE AUTOMATIC-CONTROL RELAY (4HV)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
AMM 36-12-52-000-001 Removal of the Crossbleed Valve (6HV)
AMM 36-12-52-400-001 Installation of the Crossbleed Valve (6HV)
R AMM 49-00-00-860-003 APU Start by External Power (GTCP 36-300)
R AMM 49-00-00-860-004 APU Shutdown by External Power (GTCP 36-300) AMM 49-00-00-860-005 APU Start by External Power (APS 3200) AMM 49-00-00-860-006 APU Shutdown by External Power (APS 3200) AMM 49-00-00-860-008 APU Start by External Power (131-9(A)) AMM 49-00-00-860-009 APU Shutdown by External Power (131-9(A)) ASM 36-12/01
3. Fault Confirmation
__________________
R **ON A/C 001-049, 101-105, 151-199, 201-210,
A. Test
(1)
Start the APU (Ref. AMM TASK 49-00-00-860-008).
(2)
On the AIR COND panel 30VU:
(a)
Make sure that:
-
the APU BLEED p/bsw ON legend shows on.
-
the OFF legend on the PACK 1 and the PACK 2 p/bsw shows off.
(b)
Set the X BLEED selector to the OPEN position.
1 -EFF : ALL
-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 210
--May 01/05 ---CES -
(3) Do the operational test of both BMCs (Ref. AMM TASK 36-11-00-740-001).
(4) Stop the APU (Ref. AMM TASK 49-00-00-860-009).
**ON A/C 051-099,
A. Test
(1)
Start the APU (Ref. AMM TASK 49-00-00-860-003).
(2)
On the AIR COND panel 30VU:
(a)
Make sure that:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(107)