-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 265
--May 01/04R ---CES -
-refer to Para. 4.C.
* if the impedance is more than 3 KOhms:
-replace the ELEMENT-OVERHEAT SENSING (58HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
. if the impedance is more than 3 KOhms:
-disconnect the connector between the sensing elements 78HF and 56HF
-connect the connector between the sensing elements 58HF and 78HF
-do a check of the impedance read on the LOOP CONTROLLER (9240SI).
* if the impedance is less than 3 KOhms:
-replace the OVHT SENS ELEMENT (78HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
* if the impedance is more than 3 KOhms:
-replace the SNSG ELEM-OVHT, L WING LOOP B (56HF) (Ref. AMM TASK 36-22-16-000-001) and (Ref. AMM TASK 36-22-16-400-001)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
2 If the impedance is more than 3 KOhms:
_ -disconnect the connector between the cables 52HF and 51HF
-connect the connector between the sensing elements 56HF and 55HF
-do a check of the impedance read on the LOOP CONTROLLER (9240SI).
a If the impedance is less than 3 KOhms:
_
-disconnect the connector between the sensing elements 54HF and 53HF
-do a check of the impedance read on the LOOP CONTROLLER (9240SI). . if the impedance is less than 3 KOhms:
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 266
--May 01/04R ---CES -
-disconnect the connector between the sensing elements 55HF and 54HF
-do a check of the impedance read on the LOOP CONTROLLER (9240SI).
* if the impedance is less than 3 KOhms:
-replace the SNSG ELEM-OVHT, L WING LOOP B (55HF) (Ref. AMM TASK 36-22-16-000-006) and (Ref. AMM TASK 36-22-16-400-007)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
* if the impedance is more than 3 KOhms:
-replace the SNSG ELEM-OVHT, L WING LOOP B (54HF) (Ref. AMM TASK 36-22-16-000-005) and (Ref. AMM TASK 36-22-16-400-005)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
. if the impedance is more than 3 KOhms:
-disconnect the connector between the sensing element 53HF and the cable 52HF
-connect the connector between the sensing elements 54HF and 53HF
-do a check of the impedance read on the LOOP CONTROLLER (9240SI).
* if the impedance is less than 3 KOhms:
-replace the SNSG ELEM-OVHT, L WING LOOP B (53HF) (Ref. AMM TASK 36-22-16-000-004) and (Ref. AMM TASK 36-22-16-400-004)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
* if the impedance is more than 3 KOhms:
-replace the CABLE-CONNECTING, L WING LOOP B (52HF) (Ref. AMM TASK 36-22-16-000-007) and (Ref. AMM TASK 36-22-16-400-008)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(136)