 -do a check of the impedance read on the LOOP CONTROLLER (9240SI). . if the impedance is less than 3 KOhms:
 -disconnect the connector between the cable 59HF and 58HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the ELEMENT-OVERHEAT SENSING (59HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 265
 --May 01/04R ---CES -


 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the ELEMENT-OVERHEAT SENSING (58HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 . if the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing elements 78HF and 56HF
 -connect the connector between the sensing elements 58HF and 78HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the OVHT SENS ELEMENT (78HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the SNSG ELEM-OVHT, L WING LOOP B (56HF) (Ref. AMM TASK 36-22-16-000-001) and (Ref. AMM TASK 36-22-16-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 2 If the impedance is more than 3 KOhms:
_ -disconnect the connector between the cables 52HF and 51HF
 -connect the connector between the sensing elements 56HF and 55HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 a If the impedance is less than 3 KOhms:
_
 -disconnect the connector between the sensing elements 54HF and 53HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI). . if the impedance is less than 3 KOhms:
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 266
 --May 01/04R ---CES -


 -disconnect the connector between the sensing elements 55HF and 54HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the SNSG ELEM-OVHT, L WING LOOP B (55HF) (Ref. AMM TASK 36-22-16-000-006) and (Ref. AMM TASK 36-22-16-400-007)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the SNSG ELEM-OVHT, L WING LOOP B (54HF) (Ref. AMM TASK 36-22-16-000-005) and (Ref. AMM TASK 36-22-16-400-005)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 . if the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing element 53HF and the cable 52HF
 -connect the connector between the sensing elements 54HF and 53HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the SNSG ELEM-OVHT, L WING LOOP B (53HF) (Ref. AMM TASK 36-22-16-000-004) and (Ref. AMM TASK 36-22-16-400-004)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the CABLE-CONNECTING, L WING LOOP B (52HF) (Ref. AMM TASK 36-22-16-000-007) and (Ref. AMM TASK 36-22-16-400-008)
 