R a_ If the impedance is less than 3 KOhms:
R - disconnect the connector between the sensing elements
R 16HF and 17HF
R - do a check of the impedance read on the LOOP CONTROLLER
R (9240SI)
R (AA) if the impedance is less than 3 KOhms:
R - replace the OVHT SENS ELEMENT (16HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)
R - connect all the cables or connectors disconnected
R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1
R connector
R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-R 001),
R - refer to Para. 4.B.
1
R -EFF : 301-399,
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 293
--May 01/04 ---CES -R (AB) if the impedance is more than 3 KOhms: R - replace the OVHT SENS ELEMENT (17HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001) R - connect all the cables or connectors disconnected R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 R connector R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-R 001) R - refer to Para. 4.B.
R b_ If the impedance is more than 3 KOhms:R - connect the connector between the sensing elements 17HF R and 18HF R - disconnect the connector between the sensing element 19HF R and the cable 20HF R - do a check of the impedance read on the LOOP CONTROLLER R (9240SI) R (AA) if the impedance is less than 3 KOhms: R - disconnect the connector between the sensing elements R 18HF and 19HF R - do a check of the impedance read on the LOOP CONTROLLER R (9240SI). R (1.1) if the impedance is less than 3 KOhms: R - replace the OVHT SENS ELEMENT (18HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001) R - connect all the cables or connectors disconnected R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 R connector R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-R 001) R - refer to Para. 4.B. R (1.2) if the impedance is more than 3 KOhms: R - replace the OVHT SENS ELEMENT (19HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001) R - connect all the cables or connectors disconnected R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 R connector R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-R 001) R - refer to Para. 4.B. R (AB) if the impedance is more than 3 KOhms: R - replace the CABLE ASSY (20HF) (Ref. AMM TASK 36-22-17-R 000-001) and (Ref. AMM TASK 36-22-17-400-001) R - connect all the cables or connectors disconnected R - do a check of the impedance read on the LOOP CONTROLLER R (9240SI) R (aa) if the impedance is less than 3 KOhms: R - do a check and repair the wiring between the pin AA/8B R of the BMC1 (1HA1) and the cable 20HF R - connect all the cables or connector disconnected R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 R connector
1
R -EFF : 301-399,
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 294
--May 01/04 ---CES -
R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-
R 001)
R - refer to Para. 4.B.
R (ab) if the impedance is more than 3 KOhms:
R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1
R connector
R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-
R 001)
R - refer to Para. 4.B.
R **ON A/C ALL
B. Do the test given in para. 3.
1 -EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 295
--May 01/04 ---CES - Leak Detection on the Engine 1 Pylon
1. Possible Causes
_______________
-BMC-1 (1HA1)
-CABLE-CONNECTING, ENG 1 PYLON (2HF1)
-SNSG ELEM-OVHT, ENG 1 PYLON (1HF1)
-CABLE ASSY (3HF1)
-wiring
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
9240SI 1 LOOP CONTROLLER
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
AMM 36-22-15-000-001 Removal of the Pylon Overheat Sensing Element (1HF1,