 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.

 (b)
 If no sensing element is damaged:


 -disconnect the connector between the sensing elements 56HF and 55HF
 -connect the LOOP CONTROLLER (9240SI) between the connector 1HA2-AA/5D and the ground
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 1_ If the impedance is less than 3 KOhms:
 - disconnect the connector between the sensing elements 60HF
 and 59HF
 - do a check of the impedance read on the LOOP CONTROLLER
 (9240SI).

 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 263
 --May 01/04R ---CES -

 a
_

If the impedance is less than 3 KOhms:
 -disconnect the connector between the sensing elements 63HF and 62HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI). . if the impedance is less than 3 KOhms:
 -disconnect the connector between the cable 57HF and the
 sensing element 63HF

 -do a check of the impedance read on the LOOP CONTROLLER
 (9240SI)

 * if the impedance is less than 3 KOhms:

 -replace the CABLE-CONNECTING (57HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)

 -
do a check of the impedance read on the LOOP CONTROLLER
 (9240SI).
 ** if the impedance is less than 3 KOhms:


 -
do a check and repair the wiring between the pin AA/5D
 of the BMC2 (1HA2) and the cable 57HF

 

 -connect all the cables or connectors disconnected

 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2
 connector

 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)

 -refer to Para. 4.C.
 ** if the impedance is more than 3 KOhms:

 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the ELEMENT-OVERHEAT SENSING (63HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 . if the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing elements 62HF and 61HF
 -connect the connector between the sensing elements 63HF and 62HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the ELEMENT-OVERHEAT SENSING (62HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 264
 --May 01/04R ---CES -

 b
_

 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -disconnect the connector between the sensing elements 61HF and 60HF
 -connect the connector between the sensing elements 62HF and 61HF
 -do a check of the impedance read in the LOOP CONTROLLER (9240SI). ** if the impedance is less than 3 KOhms:
 -replace the OVHT SENS ELEMENT (61HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 ** if the impedance is more than 3 KOhms:

 -replace the ELEMENT-OVERHEAT SENSING (60HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
 -install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
If the impedance is more than 3 KOhms:
 -disconnect the connector between the sensing elements 58HF and 78HF
 -connect the connector between the cables 60HF and 59HF
 