R  - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400- 
R  001)  
R  - refer to Para. 4.B.  
R  
R  * If the impedance is more than 3 KOhms:  
R  - replace the OVHT SENS ELEMENT (13HF) (Ref. AMM TASK 36- 
R  22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)  
R  - connect all the cables or connectors disconnected  
R  - disconnect the LOOP CONTROLLER (9240SI) from the BMC1  
R  connector  
R  - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400- 
R  001)  
R  - refer to Para. 4.B.  
R  2_  If the impedance is more than 3 KOhms: 
R  - connect the connector between the sensing elements 13HF and  
R  14HF  
R  - disconnect the connector between the sensing elements 14HF  
R  and 15HF  
R  - do an impedance check read on the LOOP CONTROLLER (9240SI).  
R  a_  If the impedance is less than 3 KOhms: 
R  - replace the OVHT SENS ELEMENT (14HF) (Ref. AMM TASK 36- 
R  22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)  
R  - connect all the cables or connectors disconnected  
R  - disconnect the LOOP CONTROLLER (9240SI) from the BMC1  
R  connector  
R  - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)  
R  - refer to Para. 4.B.  
R  b_  If the impedance is more than 3 KOhms: 
R  - replace the OVHT SENS ELEMENT (15HF) (Ref. AMM TASK 36- 
R  22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001)  
R  - connect all the cables or connectors disconnected  
R  - disconnect the LOOP CONTROLLER (9240SI) from the BMC1  
R  connector  
R  - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)  
R  - refer to Para. 4.B.  
R  (f) If the impedance is more than 3 KOhms:  
R  - connect the connector between the sensing element 15HF and 16HF  
R  - disconnect the connector between the sensing elements 17HF and  
R  18HF  
R  - do a check of the impedance read on the LOOP CONTROLLER  
R  (9240SI).  
R  1_  If the impedance is less than 3 KOhms: 
R  - disconnect the connector between the sensing elements 16HF  
R  and 17HF  
R  - do an impedance check on the LOOP CONTROLLER (9240SI).
 1 
R -EFF : 301-399,
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 249
 --May 01/04 ---CES -
R a_ If the impedance is less than 3 KOhms:
R - replace the OVHT SENS ELEMENT (16HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001) 
R - connect all the cables or connectors disconnected 
R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 
R connector 
R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001), 
R - refer to Para. 4.B.
R b_ If the impedance is more than 3 KOhms:
R - replace the OVHT SENS ELEMENT (17HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001) 
R - connect all the cables or connectors disconnected 
R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 
R connector 
R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001) 
R - refer to Para. 4.B.
R 2_ If the impedance is more than 3 KOhms:
R - connect the connector between the sensing elements 17HF and 
R 18HF 
R - disconnect the connector between the sensing element 19HF 
R and the cable 20HF 
R - do an impedance check on the LOOP CONTROLLER (9240SI).
R a_ If the impedance is less than 3 KOhms:
R - disconnect the connector between the sensing elements 
R 18HF and 19HF 
R - do an impedance check on the LOOP CONTROLLER (9240SI). 
R 
R * If the impedance is less than 3 KOhms: 
R - replace the OVHT SENS ELEMENT (18HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001) 
R - connect all the cables or connectors disconnected 
R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 
R connector 
R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001) 
R - refer to Para. 4.B. 
R 
R * If the impedance is more than 3 KOhms: 
R - replace the OVHT SENS ELEMENT (19HF) (Ref. AMM TASK 36-R 22-17-000-001) and (Ref. AMM TASK 36-22-17-400-001) 
R - connect all the cables or connectors disconnected 
R - disconnect the LOOP CONTROLLER (9240SI) from the BMC1 
R connector 
R - install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001) 
 