 -INLET GUIDE VANE ACTR (8014KM) (Ref. TASK 49-00-00-810-824),
 -LOAD CTL VALVE (8050KM) (Ref. TASK 49-00-00-810-829).
R **ON A/C 106-149, 211-299, 301-399, 401-499,
 A. If the self test gives the maintenance message:
 -
BLEED CTL VLV P33 P24 (Ref. TASK 49-00-00-810-904),

 -
BLEED FLOW XDCR P24 (Ref. TASK 49-00-00-810-903),


 -
INLET TEMP/PRESS SNSR P22 (Ref. TASK 49-00-00-810-908),

 -
INLET GUIDE VANE ACTR P21 (Ref. TASK 49-00-00-810-905),


 -LCDT SNSR P29 (Ref. TASK 49-00-00-810-907).
 **ON A/C 001-049, 101-105, 151-199, 201-210,
 B. Maintenance Action
 (1)
 If the test gives the Warning AIR APU FAULT on the EWD:

 -do the trouble shooting of the APU bleed-air output (Ref. TASK 49-00-81-810-856).

 (2)
 If the fault continues:

 -replace the APU BLEED P/BSW (5HV) on panel 30VU.

 (3)
 If the fault continues:


 -do a check and repair if necessary the wiring between: the BMC-1, BMC-2 connector AB/6A and the ECB (ELECTRONIC CONTROL BOX) (59KD) connector AB/D6 (Ref. ASM 36-12/00).
 1 -EFF : ALL

-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 206
 --Aug 01/05 ---CES -


R  (4) If the fault continues: 
R  - do a check and repair the wiring if necessary between: 
R  the BMC-1, BMC-2 connector AA/14C and the APU BLEED P/BSW (5HV) 
R  connector A/B1 (Ref. ASM 36-12/00), 
R  the APU BLEED P/BSW (5HV) connector A/B3 and GND (Ref. ASM 36-
12/00). 
R  (5) If the fault continues: 
R  - do a check and repair the wiring if necessary between: 
R  the BMC-1, BMC-2 connector AA/15C and the APU LOAD-CONTROL VALVE 
R  connector P/33 (Ref. ASM 36-12/00), 
R  the APU LOAD-CONTROL VALVE connector P4 and GND (Ref. ASM 36-
12/00). 
R  (6) If the fault continues: 
R  - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. 
R  AMM TASK 49-61-34-400-003). 
R  (7) If the fault continues: 
R  - replace the BMC-1 (1HA1) or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-
R  34-000-001) and (Ref. AMM TASK 36-11-34-400-001). 
R  **ON A/C 051-099, 
R  B. Maintenance Action 
R  (1) If the test gives the maintenance message AIR APU FAULT on the EWD: 
R  - do the trouble shooting of the APU bleed-air output (Ref. TASK 49-
R  00-00-810-829), (Ref. TASK 49-50-00-810-802) and (Ref. TASK 49-00-
R  00-810-847). 
R  (2) If the test gives that the APU supplies 
R  . no bleed-air pressure 
R  or 
R  . low or fluctuating bleed-air pressure: 
R  - do the related trouble shooting task (Ref. TASK 49-00-00-810-847) 
R  or (Ref. TASK 49-00-00-810-847). 
R  (3) If the fault continues: 
R  - replace the APU BLEED P/BSW (5HV) on panel 30VU. 
R  (4) If the fault continues: 
R  - do a check and repair if necessary the wiring between: 
R  the BMC-1, BMC-2 connector AB/6A and the ECB (ELECTRONIC CONTROL 
R  BOX) (59KD) connector AB/D6 (Ref. ASM 36-12/00).

 1
R -EFF : 001-049, 051-099, 101-105, 151-199,

-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 207
 -201-210, -May 01/05 ---CES -


 (5)
 If the fault continues:

 -do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/14C and the APU BLEED P/BSW (5HV) connector A/B1 (Ref. ASM 36-12/00), the APU BLEED P/BSW (5HV) connector A/B3 and GND (Ref. ASM 36-12/00).

 (6)
 If the fault continues:

 -do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/15C and the APU LOAD-CONTROL VALVE connector P/33 (Ref. ASM 36-12/00), the APU LOAD-CONTROL VALVE connector P4 and GND (Ref. ASM 36-12/00).

 (7)
 If the fault continues:

 -replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).

 (8)
 If the fault continues:


 -replace the BMC-1 (1HA1) or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
R **ON A/C 106-149, 211-299, 301-399, 401-499,
 B. Maintenance ACtion
 (1)
 If the test gives the maintenance message AIR APU FAULT on the EWD:

 -do the trouble shooting of the APU bleed outlet (Ref. TASK 49-00-00-810-904).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(106)