BLEED FLOW XDCR P24 (Ref. TASK 49-00-00-810-903),
-
INLET TEMP/PRESS SNSR P22 (Ref. TASK 49-00-00-810-908),
-
INLET GUIDE VANE ACTR P21 (Ref. TASK 49-00-00-810-905),
-LCDT SNSR P29 (Ref. TASK 49-00-00-810-907).
**ON A/C 001-049, 101-105, 151-199, 201-210,
B. Maintenance Action
(1)
If the test gives the Warning AIR APU FAULT on the EWD:
-do the trouble shooting of the APU bleed-air output (Ref. TASK 49-00-81-810-856).
(2)
If the fault continues:
-replace the APU BLEED P/BSW (5HV) on panel 30VU.
(3)
If the fault continues:
-do a check and repair if necessary the wiring between: the BMC-1, BMC-2 connector AB/6A and the ECB (ELECTRONIC CONTROL BOX) (59KD) connector AB/D6 (Ref. ASM 36-12/00).
1 -EFF : ALL
-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 206
--Aug 01/05 ---CES -
R (4) If the fault continues:
R - do a check and repair the wiring if necessary between:
R the BMC-1, BMC-2 connector AA/14C and the APU BLEED P/BSW (5HV)
R connector A/B1 (Ref. ASM 36-12/00),
R the APU BLEED P/BSW (5HV) connector A/B3 and GND (Ref. ASM 36-
12/00).
R (5) If the fault continues:
R - do a check and repair the wiring if necessary between:
R the BMC-1, BMC-2 connector AA/15C and the APU LOAD-CONTROL VALVE
R connector P/33 (Ref. ASM 36-12/00),
R the APU LOAD-CONTROL VALVE connector P4 and GND (Ref. ASM 36-
12/00).
R (6) If the fault continues:
R - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref.
R AMM TASK 49-61-34-400-003).
R (7) If the fault continues:
R - replace the BMC-1 (1HA1) or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-
R 34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
R **ON A/C 051-099,
R B. Maintenance Action
R (1) If the test gives the maintenance message AIR APU FAULT on the EWD:
R - do the trouble shooting of the APU bleed-air output (Ref. TASK 49-
R 00-00-810-829), (Ref. TASK 49-50-00-810-802) and (Ref. TASK 49-00-
R 00-810-847).
R (2) If the test gives that the APU supplies
R . no bleed-air pressure
R or
R . low or fluctuating bleed-air pressure:
R - do the related trouble shooting task (Ref. TASK 49-00-00-810-847)
R or (Ref. TASK 49-00-00-810-847).
R (3) If the fault continues:
R - replace the APU BLEED P/BSW (5HV) on panel 30VU.
R (4) If the fault continues:
R - do a check and repair if necessary the wiring between:
R the BMC-1, BMC-2 connector AB/6A and the ECB (ELECTRONIC CONTROL
R BOX) (59KD) connector AB/D6 (Ref. ASM 36-12/00).
1
R -EFF : 001-049, 051-099, 101-105, 151-199,
-∞∞36-12-00∞∞∞∞∞∞∞∞∞∞Page 207
-201-210, -May 01/05 ---CES -
(5)
If the fault continues:
-do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/14C and the APU BLEED P/BSW (5HV) connector A/B1 (Ref. ASM 36-12/00), the APU BLEED P/BSW (5HV) connector A/B3 and GND (Ref. ASM 36-12/00).
(6)
If the fault continues:
-do a check and repair the wiring if necessary between: the BMC-1, BMC-2 connector AA/15C and the APU LOAD-CONTROL VALVE connector P/33 (Ref. ASM 36-12/00), the APU LOAD-CONTROL VALVE connector P4 and GND (Ref. ASM 36-12/00).
(7)
If the fault continues:
-replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
(8)
If the fault continues:
-replace the BMC-1 (1HA1) or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
R **ON A/C 106-149, 211-299, 301-399, 401-499,
B. Maintenance ACtion
(1)
If the test gives the maintenance message AIR APU FAULT on the EWD:
-do the trouble shooting of the APU bleed outlet (Ref. TASK 49-00-00-810-904). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(106)