Internal Failure of the BMC1
 1. Possible Causes
_______________
 -BMC-1 (1HA1)
 -XDCR-BLEED TRANSFER PRESS, ENG 1 (7HA1)
 -SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1)
 -wiring
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 36-11-00-740-001 BITE Test of the BMC 1(2) AMM 36-11-15-000-001 Removal of the Bleed Transferred Pressure Transducer (7HA1,7HA2) AMM 36-11-15-400-001 Installation of the Bleed Transferred Pressure Transducer (7HA1,7HA2) AMM 36-11-17-000-001 Removal of the Heat-Exchanger Outlet-Temperature Sensor 6HA1(6HA2) AMM 36-11-17-400-001 Installation of the Heat-Exchanger Outlet-Temperature
 Sensor 6HA1(6HA2)
 AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
 AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
 ASM 36-11/01
 3. Fault Confirmation
__________________
 A. Test Do the BITE test of the BMC1 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________ 
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-228, 301-302,
 A. If the test gives the maintenance message:
 CHECK BMC1
 -replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 1 -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A292
 --May 01/05 ---CES - (1) If the fault continues:
 -replace the XDCR-BLEED TRANSFER PRESS, ENG 1 (7HA1) (Ref. AMM TASK 36-11-15-000-001) and (Ref. AMM TASK 36-11-15-400-001).
 (a) If the fault continues:
 -replace the SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1) (Ref. AMM TASK 36-11-17-000-001) and (Ref. AMM TASK 36-11-17-400-001).
 1 If the fault continues:
_
 -do a check for 28VDC at pins 1 and 2 of the bleed transferred pressure transducer (7HA1).
 a If there is no 28VDC:
_
 -do a check and repair the wiring (Ref. ASM 36-11/01) between pin 1 of the bleed transferred pressure transducer (7HA1) and the first terminal block.
 b If there is 28VDC:
_
 -do a check and repair the wiring (Ref. ASM 36-11/01) between: . pin 3 of the bleed transferred pressure transducer (7HA1) and pin AA/15B of the BMC1 (1HA1) . pin 4 of the bleed transferred pressure transducer (7HA1) and pin AA/14B of the BMC1 . pin 4 of the exchanger out temperature sensor (6HA1) and pin AA/10B of the BMC1 . pin 2 of the exchanger out temperature sensor (6HA1) and pin AA/9B of the BMC1. 
R **ON A/C 106-149, 229-299, 303-399, 401-499,
 A. If the test gives the maintenance message:
 CHECK BMC1 (1HA1)
 -replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 (1) If the fault continues:
 -replace the XDCR-BLEED TRANSFER PRESS, ENG 1 (7HA1) (Ref. AMM TASK 36-11-15-000-001) and (Ref. AMM TASK 36-11-15-400-001).
 (a) If the fault continues:
 -replace the SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1) (Ref. AMM TASK 36-11-17-000-001) and (Ref. AMM TASK 36-11-17-400-001).
 1 If the fault continues:
_
 -do a check for 28VDC at pins 1 and 2 of the bleed transferred pressure transducer (7HA1).
 1 -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A293
 --Aug 01/05 ---CES -
R  a_  If there is no 28VDC: 
R  - do a check and repair the wiring (Ref. ASM 36-11/01)  
R  between pin 1 of the bleed transferred pressure  
R  transducer (7HA1) and the first terminal block.  
R  b_  If there is 28VDC: 
R  - do a check and repair the wiring (Ref. ASM 36-11/01)  
R  between:  
R  . pin 3 of the bleed transferred pressure transducer  
R  (7HA1) and pin AA/15B of the BMC1 (1HA1)  
R  . pin 4 of the bleed transferred pressure transducer  
R  (7HA1) and pin AA/14B of the BMC1  
R  . pin 4 of the exchanger out temperature sensor (6HA1)  
R  and pin AA/10B of the BMC1  
R  . pin 2 of the exchanger out temperature sensor (6HA1)  