1 -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A229
--Feb 01/05 ---CES - Loss of or Accidental Electrical Closure of the Bleed Pressure-Regulator Valve of the Engine 2
1. Possible Causes
_______________
-SOLENOID-BLEED PRESS REG V CTL, ENG 2 (10HA2)
-P/BSW-ENG 2 BLEED (4HA2)
-AIR BLEED/ENG 2/CTL (3HA2)
-BMC-2 (1HA2)
-wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R 24-00-00-810-803 Circuit Breaker Tripped and/or C/B TRIPPED Warning AMM 36-11-00-740-001 BITE Test of the BMC 1(2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) AMM 36-11-55-000-001 Removal of the Bleed-Pressure-Regulator Valve
Control-Solenoid (10HA1,10HA2) AMM 36-11-55-400-001 Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid (10HA1,10HA2) ASM 36-11/02
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the BMC2 (Ref. AMM TASK 36-11-00-740-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU AIR BLEED/ENG 2/CTL 3HA2 Z23 122VU AIR BLEED/ENG 2/MONG 2HA2 Z22
1 -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A230
--May 01/05 ---CES -
R B. If the test gives the maintenance message:
R BMC2 OR SOLENOID 10HA2 CKT
R NOTE : If the maintenance message BMC2 OR SOLENOID 10HA2 CKT comes into____
R view with no associated ECAM warning, no trouble shooting
R procedure is necessary.
R - Do a check of the status of the circuit breaker (3HA2).
R (1) If the circuit breaker (3HA2) is closed:
R - Do a check for 28 VDC at pin A/1 of the connector of the bleed
R pressure regulator valve control solenoid (10HA2) with the ENG 2
R BLEED pushbutton switch (4HA2) released (OFF legend on).
R (a) If there is 28 VDC:
R - Do a check for ground at pin A/2 of the connector of the bleed
R pressure-regulator valve control-solenoid (10HA2).
R 1_ If there is no ground signal:
R - Repair the wiring from the pin A/2 to the ground point.
R 2_ If there is a ground signal:
R - Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 2 (10HA2)
R (Ref. AMM TASK 36-11-55-000-001) and (Ref. AMM TASK 36-11-
R 55-400-001).
R (b) If there is no 28 VDC:
R - Do a check for 28 VDC at pin A/D2 of the ENG 2 BLEED pushbutton
R switch (4HA2).
R 1_ If there is 28 VDC:
R - Replace the P/BSW-ENG 2 BLEED (4HA2).
R a_ If the fault continues:
R - Do a check and repair the wiring from the pin A/1 of the
R bleed pressure regulator valve control solenoid to the
R pin A/D3 of the ENG 2 BLEED pushbutton switch.
R 2_ If there is no 28 VDC:
R - Do a check and repair the wiring from the pin A/D2 of the
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(63)