- on the BMC2
L WING LOOP B INOP
-do this trouble shooting procedure (Ref. TASK 36-22-00-810-807) and (Ref. TASK 36-22-00-810-809).
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 232
--Feb 01/03R ---CES -
Loss of the Right-Wing Leak Detection
1.
Possible Causes
_______________
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-22-00-810-806 Loss of the Leak Detection Loop A on the Right Wing 36-22-00-810-808 Loss of the Leak Detection Loop B on the Right Wing AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the BMC1 and BMC2 (Ref. AMM TASK 36-11-00-740-001).
4. Fault Isolation
_______________
A. If the test gives these two maintenance messages;
- on the BMC1:
R WING LOOP A INOP
- on the BMC2:
CHECK R WING LOOP B
-do this trouble shooting procedure (Ref. TASK 36-22-00-810-806).
(1) Do this trouble shooting procedure (Ref. TASK 36-22-00-810-808).
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 233
--Feb 01/03R ---CES -
Loss of the Left-Wing Leak Detection
1. Possible Causes
_______________
-BMC-1 (1HA1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-22-00-810-809 Loss of the Leak Detection Loop B on the Left Wing
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the BMC1 and BMC2 (Ref. AMM TASK 36-11-00-740-001).
4. Fault Isolation
_______________
A. If the test gives these two maintenance messages:
- on the BMC1:
BMC1
-and on the BMC2:
L WING LOOP B INOP:
-replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
(1) Do this trouble shooting procedure (Ref. TASK 36-22-00-810-809).
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 234
--Feb 01/03R ---CES -
Loss of the Right-Wing Leak Detection
1. Possible Causes
_______________
-BMC-1 (1HA1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-22-00-810-808 Loss of the Leak Detection Loop B on the Right Wing
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the BMC1 and BMC2 (Ref. AMM TASK 36-11-00-740-001).
4. Fault Isolation
_______________
A. If the test gives these two maintenance messages:
- on the BMC1:
BMC1
-and on the BMC2:
R WING LOOP B INOP
-replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
(1) Do this trouble shooting procedure (Ref. TASK 36-22-00-810-808).
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 235
--Feb 01/03R ---CES -
Loss of the Left-Wing Leak Detection
1. Possible Causes
_______________
-BMC-2 (1HA2)
2. Job Set-up Information 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(122)