- on the BMC2
 L WING LOOP B INOP
 -do this trouble shooting procedure (Ref. TASK 36-22-00-810-807) and (Ref. TASK 36-22-00-810-809).
 1
 -EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 232
 --Feb 01/03R ---CES -
 Loss of the Right-Wing Leak Detection
 1.
 Possible Causes
_______________
 2.
 Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-22-00-810-806 Loss of the Leak Detection Loop A on the Right Wing 36-22-00-810-808 Loss of the Leak Detection Loop B on the Right Wing AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the BMC1 and BMC2 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives these two maintenance messages;
 - on the BMC1:
 R WING LOOP A INOP
 - on the BMC2:
 CHECK R WING LOOP B
 -do this trouble shooting procedure (Ref. TASK 36-22-00-810-806).
 (1) Do this trouble shooting procedure (Ref. TASK 36-22-00-810-808).
 1
 -EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 233
 --Feb 01/03R ---CES -
 Loss of the Left-Wing Leak Detection
 1. Possible Causes
_______________
 -BMC-1 (1HA1)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-22-00-810-809 Loss of the Leak Detection Loop B on the Left Wing
 AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
 AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
 AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the BMC1 and BMC2 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives these two maintenance messages:
 - on the BMC1:
 BMC1
 -and on the BMC2:
 L WING LOOP B INOP:
 -replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 (1) Do this trouble shooting procedure (Ref. TASK 36-22-00-810-809).
 1
 -EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 234
 --Feb 01/03R ---CES -
 Loss of the Right-Wing Leak Detection
 1. Possible Causes
_______________
 -BMC-1 (1HA1)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-22-00-810-808 Loss of the Leak Detection Loop B on the Right Wing
 AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
 AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
 AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the BMC1 and BMC2 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives these two maintenance messages:
 - on the BMC1:
 BMC1
 -and on the BMC2:
 R WING LOOP B INOP
 -replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 (1) Do this trouble shooting procedure (Ref. TASK 36-22-00-810-808).
 1
 -EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 235
 --Feb 01/03R ---CES -
 Loss of the Left-Wing Leak Detection
 1. Possible Causes
_______________
 -BMC-2 (1HA2)
2. Job Set-up Information 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(122)