-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 282
--May 01/04R ---CES -
a
_
b
_
If the impedance is less than 3 KOhms:
-disconnect the connector between the sensing elements
69HF and 68HF
-do a check of the impedance read on the LOOP CONTROLLER
(9240SI)
. if the impedance is less than 3 KOhms:
-replace the SNSG ELEM-OVHT, R WING LOOP B (69HF) (Ref.
AMM TASK 36-22-16-000-004) and (Ref. AMM TASK 36-22-16-400-004)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2
connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001),
-refer to Para. 4.C.
. if the impedance is more than 3 KOhms:
-disconnect the connector between the sensing elements
68HF and the cable 67HF
-connect the connector between the sensing elements 69HF
and 68HF
-do a check of the impedance read on the LOOP CONTROLLER
(9240SI).
* if the impedance is less than 3 KOhms:
-replace the CABLE-CONNECTING, R WING LOOP B (68HF) (Ref.
AMM TASK 36-22-16-000-007) and (Ref. AMM TASK 36-22-16-400-008)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2
connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
* if the impedance is more than 3 KOhms:
-replace the CABLE-CONNECTING, R WING LOOP B (67HF) (Ref.
AMM TASK 36-22-16-000-003) and (Ref. AMM TASK 36-22-16-400-003)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2
connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
If the impedance is more than 3 KOhms:
-disconnect the connector between the sensing elements
65HF and 82HF
-connect the connector between the cables 67HF and 66HF
-do a check of the impedance read on the LOOP CONTROLLER
(9240SI)
. if the impedance is less than 3 KOhms:
-disconnect the connector between the sensing element 65HF
and cable 66HF
-do a check of the impedance read on the LOOP CONTROLLER
(9240SI).
* if the impedance is less than 3 KOhms:
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 283
--May 01/04R ---CES -
-replace the SNSG ELEM-OVHT, R WING LOOP B (66HF) (Ref.
AMM TASK 36-22-16-000-005) and (Ref. AMM TASK 36-22-16-400-005)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2
connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
* if the impedance is more than 3 KOhms:
-replace the SNSG ELEM-OVHT, R WING LOOP B (65HF) (Ref.
AMM TASK 36-22-16-000-006) and (Ref. AMM TASK 36-22-16-400-007)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2
connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
. if the impedance is more than 3 Kohms
-connect the connector between the sensing elements 65HF
and 82HF
-disconnect the connector between the sensing element 82HF
and the cable 64HF
-do a check of the impedance read on the LOOP CONTROLLER
(9240SI)
* if the impedance is less than 3 KOhms:
-replace the SNSG ELEM-OVHT, R WING LOOP B (82HF) (Ref.
AMM TASK 36-22-16-000-001) and (Ref. AMM TASK 36-22-16-400-001)
-connect all the cables or connectors disconnected
-disconnect the LOOP CONTROLLER (9240SI) from the BMC1
connector
-install the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
* if the impedance is more than 3 KOhms:
-replace the CABLE-CONNECTING, R WING LOOP B (64HF) (Ref.
AMM TASK 36-22-16-000-002) and (Ref. AMM TASK 36-22-16-400-002)