-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 240
 -201-228, 301-302, -May 01/05 ---CES -
 (2) If the circuit breaker is open:
 -close the circuit breaker.
 (a) If the circuit breaker trips:
 -replace the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 1 If the fault continues:
_
 -do a check for a short to ground at the wiring from pin A/1 of the bleed transferred-pressure transducer (7HA2) to the circuit breaker (2HA2).
 a If there is a short to ground:
_ -repair the related wiring.
 b If there is no short to ground:
_
 -replace the C/B-BMC 2 (2HA2).
 (b) If the circuit breaker stays closed and the fault continues:
 -replace the BMC-2 (1HA2). 
R **ON A/C 106-149, 229-299, 303-399, 401-499,
 B. If the fault symptom is identified by the maintenance message TRANSF-PRESS XDCR 7HA2:
 -do a check of the status of the circuit breaker (2HA2).
 (1) If the circuit breaker is closed:
 -do a check for 28VDC at pin A/1 of the bleed transferred-pressure transducer (7HA2) (Ref. ASM 36-11/02).
 (a) If there is no 28VDC:
 -do a check for ground at pin A/2 of the bleed transferred-pressure transducer (7HA2).
 1 If there is no ground:
_
 -repair the wiring between pin A/2 of the bleed transferred-pressure transducer (7HA2) and the ground terminal.
 2 If there is ground:
_
 -do a check of the wiring between pin A/1 of the bleed transferred-pressure transducer (7HA2) and the circuit breaker (2HA2).
 a If there is no continuity:
_ -repair the above wiring.
 b If there is continuity:
_
 -replace the circuit breaker (2HA2).
 1 -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 241
 --Aug 01/05 ---CES -
R  3_  If the fault continues: 
R  - make sure that there is a 0 psig output signal (0.9VDC) on  
R  the BMC2 (1HA2) connector between pins AA/14A and AA/15B.  
R  a_  If there is no 0.9VDC: 
R  - replace the XDCR-BLEED TRANSFER PRESS, ENG 2 (7HA2) (Ref.  
R  AMM TASK 36-11-15-000-001) and (Ref. AMM TASK 36-11-15- 
R  400-001).  
R  4_  If the fault continues: 
R  - do a check and repair the wiring from the bleed  
R  transferred-pressure transducer (7HA2) to the BMC2 (1HA2),  
R  pins A/3 and A/4 to pins AA/15B and AA/14B.  
R  (b) If there is 28VDC:  
R  - replace the XDCR-BLEED TRANSFER PRESS, ENG 2 (7HA2).  
R  (2) If the circuit breaker is open:  
R  - close the circuit breaker.  
R  (a) If the circuit breaker trips:  
R  - replace the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and  
R  (Ref. AMM TASK 36-11-34-400-001).  
R  1_  If the fault continues: 
R  - do a check for a short to ground at the wiring from pin A/1  
R  of the bleed transferred-pressure transducer (7HA2) to the  
R  circuit breaker (2HA2).  
R  a_  If there is a short to ground: 
R  - repair the related wiring.  
R  b_  If there is no short to ground: 
R  - replace the C/B-BMC 2 (2HA2).  
R  (b) If the circuit breaker stays closed and the fault continues:  
R  - replace the BMC-2 (1HA2).  
R  **ON A/C ALL 
 C. After the subsequent flight, make sure that the fault does not continue.
1 -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 242
 --Feb 01/05 ---CES - Loss of the Bleed Regulated-Pressure Transducer of the Engine 1
 1. Possible Causes
_______________
 -XDCR-BLEED REGULATED PRESS, ENG 1 (8HA1)
 -BMC-1 (1HA1)
 -
wiring between pin A/1 of the bleed regulated-pressure transducer (8HA1) and the circuit breaker (2HA1)