• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 23:25来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 AMM 36-11-58-000-001 Removal of the HP Bleed Override Solenoid (11HA1,

 11HA2)
 AMM 36-11-58-400-001 Installation of the HP Bleed Override Solenoid
 (11HA1, 11HA2)

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the BITE test of the BMC1 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message:
 BMC1 OR SOLENOID 11HA1

 NOTE : If the maintenance message BMC1 OR SOLENOID 11HA1 comes into view
____ with no associated ECAM warning, no trouble shooting procedure is necessary.
 -replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 (1) If the fault continues:
 -replace the SOL-HP BLEED OVERRIDE, ENG1 (11HA1) (Ref. AMM TASK 36-11-58-000-001) and (Ref. AMM TASK 36-11-58-400-001).
 B. Do the test given in para. 3.
 1
R -EFF : 151-199, 401-499,

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B214
 --Aug 01/05 ---CES - BMC2 output failure for HP Bleed Override Solenoid of Engine 2

 


 1. Possible Causes
_______________
 -BMC-2 (1HA2)

 -SOL-HP BLEED OVERRIDE, ENG2 (11HA2)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
 AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
 AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
 AMM 36-11-58-000-001 Removal of the HP Bleed Override Solenoid (11HA1,

 11HA2) AMM 36-11-58-400-001 Installation of the HP Bleed Override Solenoid (11HA1, 11HA2)
 3. Fault Confirmation
__________________
 A. Test

 (1) Do the BITE test of the BMC2 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________

 A. If the test gives the maintenance message:
 BMC2 OR SOLENOID 11HA2

 NOTE : If the maintenance message BMC2 OR SOLENOID 11HA2 comes into view
____ with no associated ECAM warning, no trouble shooting procedure is necessary.
 -replace the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 (1) If the fault continues:
 -replace the SOL-HP BLEED OVERRIDE, ENG2 (11HA2) (Ref. AMM TASK 36-11-58-000-001) and (Ref. AMM TASK 36-11-58-400-001).
 B. Do the test given in para. 3.
 1

R -EFF : 151-199, 401-499,

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B215
 --Aug 01/05 ---CES - TASK 36-11-00-810-936

 

 HP Bleed Valve blocked in the closed position or regulation too low on Engine 1 without associated maintenance message
 1.
 Possible Causes

_______________


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-11-00-810-837  Failure of the HP Bleed Valve of the Engine 1 Blocked in the Closed Position
 3. Fault Confirmation
__________________

 A. Do the Last Leg Report Test of the BMC 1
 4. Fault Isolation
_______________

 A. If the Last Leg Report Test of the BMC 1 shows the maintenance message: 36-11-51 HP BLEED-V 4000HA1 OR SENSE LINE
 -do the following trouble shooting procedure (Ref. TASK 36-11-00-810-837)
 1
 -EFF : ALL


-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B216
 --Feb 01/05R ---CES -

 


 HP Bleed Valve blocked in the closed position or regulation too low on Engine 2 without associated maintenance message
 1.
 Possible Causes

_______________


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-11-00-810-838  Failure of the HP Bleed Valve of the Engine 2 Blocked in the Closed Position
 3. Fault Confirmation
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(91)