 (1) If the fault continues:
 -do a check and repair the clogged duct between the fan of the engine and the fan air valve (9HA2).
 B. Test

 (1)
 Do the engine start procedure.

 (2)
 Make sure that the ECAM warning AIR ENG 2 BLEED FAULT is not shown on the upper ECAM DU.


 1
 -EFF : ALL


-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A226
 --Feb 01/05R ---CES -

 

 Loss of or Accidental Automatic Closure of the Bleed Pressure-Regulator Valve of the Engine 1
 1. Possible Causes
_______________

 -SOLENOID-BLEED PRESS REG V CTL, ENG 1 (10HA1)
 -P/BSW-ENG 1 BLEED (4HA1)
 -AIR BLEED/ENG 1/CTL (3HA1)
 -BMC-1 (1HA1)
 -wiring

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
R 24-00-00-810-803 Circuit Breaker Tripped and/or C/B TRIPPED Warning AMM 36-11-00-740-001 BITE Test of the BMC 1(2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) AMM 36-11-55-000-001 Removal of the Bleed-Pressure-Regulator Valve Control-Solenoid (10HA1,10HA2) AMM 36-11-55-400-001 Installation of the Bleed-Pressure-Regulator Valve Control-Solenoid (10HA1,10HA2) ASM 36-11/01
 3. Fault Confirmation
__________________
 A. Test

 (1) Do the BITE test of the BMC1 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________

 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/ENG 1/CTL 3HA1 D12 49VU AIR BLEED/ENG 1/MONG 2HA1 D11
 1 -EFF : ALL

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A227
 --May 01/05 ---CES -


R  B. If the test gives the maintenance message: 
R  BMC1 OR SOLENOID 10HA1 CKT 
R  NOTE : If the maintenance message BMC1 OR SOLENOID 10HA1 CKT comes into____ 
R  view with no associated ECAM warning, no trouble shooting 
R  procedure is necessary. 
R  - Do a check of the status of the circuit breaker (3HA1). 
R  (1) If the circuit breaker (3HA1) is closed: 
R  - Do a check for 28 VDC at pin A/1 of the connector of the bleed 
R  pressure regulator valve control solenoid (10HA1) with the ENG 1 
R  BLEED pushbutton switch (4HA1) released (OFF legend on). 
R  (a) If there is 28 VDC: 
R  - Do a check for ground at pin A/2 of the connector of the bleed 
R  pressure regulator valve control solenoid (10HA1). 
R  1_  If there is no ground signal:
R  - Repair the wiring from the pin A/2 to the ground point. 
R  2_  If there is a ground signal:
R  - Replace the SOLENOID-BLEED PRESS REG V CTL, ENG 1 (10HA1) 
R  (Ref. AMM TASK 36-11-55-000-001) and (Ref. AMM TASK 36-11-
R  55-400-001). 
R  (b) If there is no 28 VDC: 
R  - Do a check for 28 VDC at pin A/D2 of the ENG 1 BLEED pushbutton 
R  switch (4HA1). 
R  1_  If there is 28 VDC:
R  - Replace the P/BSW-ENG 1 BLEED (4HA1). 
R  a_  If the fault continues:
R  - Do a check and repair the wiring from the pin A/1 of the 
R  bleed pressure regulator valve control solenoid to the 
R  pin A/D3 of the ENG 1 BLEED pushbutton switch. 
R  2_  If there is no 28 VDC:
R  - Do a check and repair the wiring from the pin A/D2 of the 
R  ENG 1 BLEED pushbutton switch to the pin 2 of the circuit 
R  breaker 3HA1. 
R  a_  If the fault continues:
R  - Replace the AIR BLEED/ENG 1/CTL (3HA1). 
R  (2) If the circuit breaker (3HA1) is tripped: 
R  - Do the procedure (Ref. TASK 24-00-00-810-803).

 1 -EFF : ALL

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A228
 --Feb 01/05 ---CES -


R  (3) Check of the automatic closure of the bleed pressure regulator valve 
R  (4001HA). 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(62)