 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
 AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
 AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)

 3. Fault Confirmation

__________________
 A. Test
 (1) Do the BITE test of the BMC 1 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the ECAM warning AIR ENG 1 BLEED LEAK associated with the FAULT legend on on the ENG 1 BLEED pushbutton switch:
 (1) Release and push the ENG 1 BLEED pushbutton switch to clear the warnings.
 NOTE : No further maintenance action is required if the ducts are
____
 cold and not pressurized.

 (2) If the fault continues:
 (a) Replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001)
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 240
 --Feb 01/03R ---CES -

 


 Unwanted Engine 2 Leak Detection
 1. Possible Causes
_______________
 -BMC-2 (1HA2)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-00-740-001 BITE Test of the BMC 1(2)
 AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
 AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)

 3. Fault Confirmation

__________________
 A. Test
 (1) Do the BITE test of the BMC 2 (Ref. AMM TASK 36-11-00-740-001).
 4. Fault Isolation
_______________
 A. If the test gives the ECAM warning AIR ENG 2 BLEED LEAK associated with the FAULT legend on on the ENG 2 BLEED pushbutton switch:
 (1) Release and push the ENG 2 BLEED pushbutton switch to clear the warnings.
 NOTE : No further maintenance action is required if the ducts are
____
 cold and not pressurized.

 (2) If the fault continues:
 (a) Replace the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001)
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 241
 --Feb 01/03R ---CES -


 Unwanted APU Leak Detection
 1. Possible Causes
_______________
 -BMC-1 (1HA1)
 -CONNECTING CABLE (11HF)
 -
OVHT SENS ELEMENT (12HF)

 -
OVHT SENS ELEMENT (13HF)

 -
OVHT SENS ELEMENT (14HF)

 -
OVHT SENS ELEMENT (15HF)

 -
OVHT SENS ELEMENT (16HF)

 -
OVHT SENS ELEMENT (17HF)

 -
OVHT SENS ELEMENT (18HF)

 -
OVHT SENS ELEMENT (19HF)


 -CABLE ASSY (20HF) R - OVERHEAT SENSING ELEM (84HF)
 -
wiring between the pin 7B of the BMC1 connector (1HA1-AA) and the cable 11HF

 -
wiring between the pin 8B of the BMC1 connector (1HA1-AA) and the cable 20HF


 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
9240SI 1 LOOP CONTROLLER
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) AMM 36-22-17-000-001 Removal of the APU Overheat Sensing-Elements AMM 36-22-17-400-001 Installation of the APU Overheat Sensing-Elements ASM 36-22/01
 3. Fault Confirmation
__________________
 A. Test
 (1) Not applicable.
 1 -EFF : ALL

-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 242
 --May 01/04 ---CES -

 4. Fault Isolation
_______________

R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 