 . If the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing elements 27HF and 28HF
 -connect the connector between the sensing elements 26HF and 27HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the SNSG ELEM-OVHT, L WING LOOP A (27HF) (Ref. AMM TASK 36-22-16-000-005) and (Ref. AMM TASK 36-22-16-400-005)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the SNSG ELEM-OVHT, L WING LOOP A (28HF) (Ref. AMM TASK 36-22-16-000-006) and (Ref. AMM TASK 36-22-16-400-007)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 2 If the impedance is more than 3 KOhms:
_
 -disconnect the connector between the sensing elements 32HF and 33HF
 -connect the connector between the sensing elements 28HF and 29HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 a If the impedance is less than 3 KOhms:
_
 -disconnect the connector between the sensing elements 73HF and 31HF
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 257
 --May 01/04R ---CES -


 -
do a check of the impedance read on the LOOP CONTROLLER (9240SI). . if the impedance is less than 3 KOhms:

 -disconnect the connector between the sensing elements 29HF and 73HF

 -
do a check of the impedance read on the LOOP CONTROLLER (9240SI).


 * if the impedance is less than 3 KOhms:
 -replace the SNSG ELEM-OVHT, L WING LOOP A (29HF) (Ref. AMM TASK 36-22-16-000-001) and (Ref. AMM TASK 36-22-16-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the ELEMENT-OVERHEAT SENSING (73HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 . if the impedance is more than 3 KOhms:

 -disconnect the connector between the sensing elements 31HF and 32HF
 -connect the connector between the sensing elements 73HF and 31HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:
 -replace the OVHT SENS ELEMENT (31HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 * if the impedance is more than 3 KOhms:
 -replace the OVERHEAT SENSING ELEM (32HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)
 -connect all the cables or connectors disconnected
 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
 -install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
 -refer to Para. 4.C.
 1
 -EFF : ALL


-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 258
 --May 01/04R ---CES -


 b If the impedance is more than 3 KOhms:
_
 -disconnect the connector between the sensing elements 5HF

 and 36HF
 -connect the connector between the sensing elements 32HF and 33HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI). . If the impedance is less than 3 KOhms:
 -disconnect the connector between the sensing elements 33HF and 34HF
 -do a check of the impedance read on the LOOP CONTROLLER (9240SI).
 * if the impedance is less than 3 KOhms:

 -replace the OVHT SENS ELEMENT (33HF) (Ref. AMM TASK 36-22-18-000-001) and (Ref. AMM TASK 36-22-18-400-001)

 -connect all the cables or connectors disconnected

 -disconnect the LOOP CONTROLLER (9240SI) from the BMC1
 