• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 23:25来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 36-11-43-000-001 Removal of the Fan Air Valve Control Thermostat (7170HM1, 7170HM2) AMM 36-11-43-400-001 Installation of the Fan Air Valve Control Thermostat
 (7170HM1, 7170HM2)
 AMM 36-11-54-000-001 Removal of the Fan Air Valve (9HA1,9HA2)
 AMM 36-11-54-400-001 Installation of the Fan Air Valve (9HA1,9HA2)
 ASM 36-11/01

 3. Fault Confirmation
__________________
 A. Not applicable.
 4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-228, 301-302,
 A. If the fault symptom is identified by the maintenance message FAN AIR V 9HA1 OR THRM 7170HM1 OR SENSE LINE:
 -do a check of the indication of the bleed temperature on the lower ECAM display unit.
 (1) If the indication of the bleed temperature is more than 218 deg.C
 (424.40 deg.F):
 -make sure that there are no leaks at the sense line between the fan air valve control-thermostat (7170HM1) and the fan air valve (9HA1).
 (a) If the fault continues:
 -replace the THERMOSTAT-FAN AIR VALVE CTL (7170HM1) (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).
 1 -EFF : ALL

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A203
 --May 01/05 ---CES - (2) If the fault continues:


 -do a check and repair the wiring from the fan air valve to the BMC1, pin A/1 to pin AA/12A.
 (a)
 If the fault continues:

 -do a check and repair the wiring between pin A/3 of the fan air valve and the ground terminal.

 (b)
 If the fault continues:


 -replace the VALVE-FAN AIR, ENG1 (9HA1) (Ref. AMM TASK 36-11-54-000-001) and (Ref. AMM TASK 36-11-54-400-001).
R **ON A/C 106-149, 229-299, 303-399, 401-499,
 A. If the fault symptom is identified by the maintenance message: THRM 7170HM1 OR FAN AIR VALVE 9HA1 OR SENSE LINE:
 -do a check of the indication of the bleed temperature on the lower ECAM display unit.
 (1)
 If the indication of the bleed temperature is more than 218 deg.C

 (424.40 deg.F):
 -make sure that there are no leaks at the sense line between the fan air valve control thermostat (7170HM1) and the fan air valve (9HA1).
 (a) If the fault continues:
 -replace the THERMOSTAT-FAN AIR VALVE CTL (7170HM1) (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).

 (2)
 If the fault continues:


 -do a check of the wiring (Ref. ASM 36-11/01) between: . pin A/1 of the engine 1 fan air valve (9HA1) and pin AA/12A of the BMC1 (1HA1) . pin A/3 of the engine 1 fan air valve and the ground.
 (a)
 If the wiring is not correct:

 -repair the wiring.

 (b)
 If the wiring is correct:


 -replace the VALVE-FAN AIR, ENG1 (9HA1) (Ref. AMM TASK 36-11-54-000-001) and (Ref. AMM TASK 36-11-54-400-001).
 **ON A/C ALL
 B. After the subsequent flight, make sure that the fault does not continue.
 1 -EFF : ALL

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page A204
 --Aug 01/05 ---CES - Fan Air Valve of the Engine 2 Blocked in the Closed Position

 


 1. Possible Causes
_______________
 -THERMOSTAT-FAN AIR VALVE CTL (7170HM2)
 -VALVE-FAN AIR, ENG2 (9HA2)
 -
wiring from the fan air valve to the BMC2

 -
wiring between pin A/3 of the fan air valve and the ground terminal

 -
wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 36-11-43-000-001 Removal of the Fan Air Valve Control Thermostat (7170HM1, 7170HM2) AMM 36-11-43-400-001 Installation of the Fan Air Valve Control Thermostat
 (7170HM1, 7170HM2)
 AMM 36-11-54-000-001 Removal of the Fan Air Valve (9HA1,9HA2)
 AMM 36-11-54-400-001 Installation of the Fan Air Valve (9HA1,9HA2)
 ASM 36-11/02

 3. Fault Confirmation
__________________
 A. Not applicable.
 4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-228, 301-302,
 A. If the fault symptom is identified by the maintenance message FAN AIR V 9HA2 OR THRM 7170HM2 OR SENSE LINE:
 -do a check of the indication of the bleed temperature on the lower ECAM display unit.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(54)