• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 23:25来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 3. Fault Confirmation
__________________
 A. Not applicable.
 4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-228, 301-302,
 A. If the fault symptom is identified by the maintenance message: FAN AIR V 9HA1 or THRM 7170HM1 or SENSE LINE
 -do a check of the unions and clamps of the sense line between the fan air valve control thermostat and the fan air valve.
 1 -EFF : ALL

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 203
 --May 01/05 ---CES -


 (1)
 If the unions are loose:

 -tighten them.

 (2)
 If the unions are correctly tightened:


 -do a check of the filter of the fan air valve control thermostat (7170HM1).
 (a)
 If the filter is clogged:

 -clean (Ref. AMM TASK 36-11-43-100-001) or replace (Ref. AMM TASK 36-11-43-000-003) and (Ref. AMM TASK 36-11-43-400-003) the filter of the thermostat (7170HM1) as necessary.

 (b)
 If the filter is not clogged:


 -replace the THERMOSTAT-FAN AIR VALVE CTL (7170HM1) (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).
 -disconnect the sense line from the fan air valve control thermostat (7170HM1) and put a blanking cap on the sense line
 -do a check of the opening of the fan air valve. Slowly apply 20 psi (1.3789 bar) at its test port (Ref. AMM TASK 36-11-54-720-001). The visual indicator must show that the fan air valve is fully open.
 1_ If the fan air valve opens fully:
 - replace the THERMOSTAT-FAN AIR VALVE CTL (7170HM1) (Ref. AMM
 TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).

 2 If the fan air valve does not open fully:
_
 -connect the sense line to the fan air valve control thermostat (7170HM1),
 -disconnect the sense line union from the fan air valve (9HA1) and put a blanking cap on the union of the fan air valve
 -do a check of the opening of the fan air valve. Slowly apply 20 psi (1.3789 bar) at its test port (Ref. AMM TASK 36-11-54-720-001).
 a If the fan air valve does not open:
_
 -replace the VALVE-FAN AIR, ENG1 (9HA1) (Ref. AMM TASK 36-11-54-000-001) and (Ref. AMM TASK 36-11-54-400-001).
 b If the fan air valve opens:
_ -do a leakage check of the sense line.
 * If the fault continues:
 * - replace the SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1)
 (Ref. AMM TASK 36-11-17-000-001) and (Ref. AMM TASK 36-11-17-400-001).

 1
R -EFF : 001-049, 051-099, 101-105, 151-199,

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 204
 -201-228, 301-302, -May 01/05 ---CES -R **ON A/C 106-149, 229-299, 303-399, 401-499,


 A. If the fault symptom is identified by the maintenance message: THRM 7170HM1 OR FAN AIR VALVE 9HA1 OR SENSE LINE
 -do a check of the unions and clamps of the sense line between the fan air valve control thermostat and the fan air valve.
 (1)
 If the unions are loose:

 -tighten them.

 (2)
 If the unions are correctly tightened:


 -do a check of the filter of the fan air valve control thermostat (7170HM1).
 (a)
 If the filter is clogged:

 -clean (Ref. AMM TASK 36-11-43-100-001) or replace (Ref. AMM TASK 36-11-43-000-003) and (Ref. AMM TASK 36-11-43-400-003) the filter of the thermostat (7170HM1) as necessary.

 (b)
 If the filter is not clogged:


 -replace the THERMOSTAT-FAN AIR VALVE CTL (7170HM1) (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001)
 -disconnect the sense line from the fan air valve control thermostat (7170HM1) and put a blanking cap on the sense line
 -do a check of the opening of the fan air valve. Slowly apply 20 psi (1.3789 bar) at its test port (Ref. AMM TASK 36-11-54-720-001). The visual indicator must show that the fan air valve is fully open.
 1 If the fan air valve opens fully:
_
 -replace the THERMOSTAT-FAN AIR VALVE CTL (7170HM1) (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).
 2 If the fan air valve does not open fully:
_
 -connect the sense line to the fan air valve control thermostat (7170HM1)
 -disconnect the sense line union from the fan air valve (9HA1) and put a blanking cap on the union of the fan air valve
 -do a check of the opening of the fan air valve. Slowly apply 20 psi (1.3789 bar) at its test port (Ref. AMM TASK 36-11-54-720-001).
 a If the fan air valve does not open:
_
 -replace the VALVE-FAN AIR, ENG1 (9HA1) (Ref. AMM TASK 36-11-54-000-001) and (Ref. AMM TASK 36-11-54-400-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(20)