wiring from the exchanger outlet temperature-sensor (6HA2) to the BMC2 (1HA2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-17-000-001 Removal of the Heat-Exchanger Outlet-Temperature Sensor 6HA1(6HA2) AMM 36-11-17-400-001 Installation of the Heat-Exchanger Outlet-Temperature
Sensor 6HA1(6HA2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) ASM 36-11/02
3. Fault Confirmation
__________________
A. Test.
(1) Not applicable, the fault is evident.
4. Fault Isolation
_______________
A. If the fault symptom is identified by the maintenance message:
TEMP SENSOR 6HA2:
-replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 (6HA2) (Ref. AMM TASK 36-11-17-000-001) and (Ref. AMM TASK 36-11-17-400-001).
(1) If the fault continues:
-do a check for ground at pin A/1 of the exchanger outlet temperature-sensor of the engine 2.
(a) If there is no ground:
-do a check and repair the wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA2) and the ground terminal (Ref. ASM 36-11/02).
1
-EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 253
--Feb 01/05R ---CES -
(b) If there is ground:
-do a check and repair the wiring from the exchanger outlet temperature-sensor (6HA2) to the BMC2 (1HA2), pins A/2 and A/4 to pins AA/9B and AA/10B.
(2) If the fault continues:
-replace the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
B. After the subsequent flight, make sure that the fault does not continue.
1
-EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 254
--Feb 01/05R ---CES -
Loss of the Two Sensing Elements of the Exchanger Outlet Temperature-Sensor of the Engine 1
1. Possible Causes
_______________
-SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1)
-BMC-1 (1HA1)
-BMC-2 (1HA2)
-
wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA1) and th ground terminal
-
wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC1 (1HA1)
-
wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC2 (1HA2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-17-000-001 Removal of the Heat-Exchanger Outlet-Temperature Sensor 6HA1(6HA2) AMM 36-11-17-400-001 Installation of the Heat-Exchanger Outlet-Temperature
Sensor 6HA1(6HA2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) ASM 36-11/01 ASM 36-11/02
3. Fault Confirmation
__________________
A. Test.
(1) Not applicable, the fault is evident.
1
-EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 255
--Feb 01/05R ---CES -
4. Fault Isolation
_______________
A. If the fault symptom is identified by the maintenance message: TEMP SENSOR 6HA1
-replace the SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1) (Ref. AMM TASK 36-11-17-000-001) and (Ref. AMM TASK 36-11-17-400-001).
(1)
If the fault continues:
-do a check for ground at pin A/1 of the exchanger outlet temperature-sensor (6HA1).
(a)
If there is no ground:
-do a check and repair the wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA1) and th ground terminal (Ref. ASM 36-11/01).
(b)
If there is ground:
-
do a check and repair the wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC1 (1HA1), pins A/2 and A/4 to pins AA/9B and AA/10B
-
do a check and repair the wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC2 (1HA2), pins A/4 and A/5 to pins AA/6D and AA/7D (Ref. ASM 36-11/02).
(2)
If the fault continues:
-replace the BMC-1 (1HA1) and/or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).