wiring from the exchanger outlet temperature-sensor (6HA2) to the BMC2 (1HA2)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-17-000-001 Removal of the Heat-Exchanger Outlet-Temperature Sensor 6HA1(6HA2) AMM 36-11-17-400-001 Installation of the Heat-Exchanger Outlet-Temperature
 Sensor 6HA1(6HA2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) ASM 36-11/02
 3. Fault Confirmation
__________________
 A. Test.

 (1) Not applicable, the fault is evident.
 4. Fault Isolation
_______________

 A. If the fault symptom is identified by the maintenance message:
 TEMP SENSOR 6HA2:

 -replace the SENSOR-EXCHANGER OUT TEMP, ENG 2 (6HA2) (Ref. AMM TASK 36-11-17-000-001) and (Ref. AMM TASK 36-11-17-400-001).
 (1) If the fault continues:
 -do a check for ground at pin A/1 of the exchanger outlet temperature-sensor of the engine 2.
 (a) If there is no ground:
 -do a check and repair the wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA2) and the ground terminal (Ref. ASM 36-11/02).
 1
 -EFF : ALL


-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 253

 --Feb 01/05R ---CES -

 

 (b) If there is ground:
 -do a check and repair the wiring from the exchanger outlet temperature-sensor (6HA2) to the BMC2 (1HA2), pins A/2 and A/4 to pins AA/9B and AA/10B.
 (2) If the fault continues:
 -replace the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 B. After the subsequent flight, make sure that the fault does not continue.
 1
 -EFF : ALL


-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 254
 --Feb 01/05R ---CES -


 Loss of the Two Sensing Elements of the Exchanger Outlet Temperature-Sensor of the Engine 1
 1. Possible Causes
_______________
 -SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1)
 -BMC-1 (1HA1)
 -BMC-2 (1HA2)
 -
wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA1) and th ground terminal

 -
wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC1 (1HA1)

 -
wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC2 (1HA2)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-17-000-001 Removal of the Heat-Exchanger Outlet-Temperature Sensor 6HA1(6HA2) AMM 36-11-17-400-001 Installation of the Heat-Exchanger Outlet-Temperature
 Sensor 6HA1(6HA2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) ASM 36-11/01 ASM 36-11/02
 3. Fault Confirmation
__________________
 A. Test.
 (1) Not applicable, the fault is evident.
 1
 -EFF : ALL


-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 255
 --Feb 01/05R ---CES -

 4. Fault Isolation
_______________

 A. If the fault symptom is identified by the maintenance message: TEMP SENSOR 6HA1
 -replace the SENSOR-EXCHANGER OUT TEMP, ENG 1 (6HA1) (Ref. AMM TASK 36-11-17-000-001) and (Ref. AMM TASK 36-11-17-400-001).
 (1)
 If the fault continues:

 -do a check for ground at pin A/1 of the exchanger outlet temperature-sensor (6HA1).
 (a)
 If there is no ground:

 -do a check and repair the wiring between pin A/1 of the exchanger outlet temperature-sensor (6HA1) and th ground terminal (Ref. ASM 36-11/01).

 (b)
 If there is ground:

 -
do a check and repair the wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC1 (1HA1), pins A/2 and A/4 to pins AA/9B and AA/10B

 -
do a check and repair the wiring from the exchanger outlet temperature-sensor (6HA1) to the BMC2 (1HA2), pins A/4 and A/5 to pins AA/6D and AA/7D (Ref. ASM 36-11/02).

 

 

 (2)
 If the fault continues:


 -replace the BMC-1 (1HA1) and/or the BMC-2 (1HA2) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 