-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B205
--Feb 01/05R ---CES -
1_ If the fault continues:
- do a check for a short to ground at the wiring from pin A/1
of the bleed regulated-pressure transducer (8HA1) to the
circuit breaker (2HA1).
a If there is a short to ground:
_
-replace the C/B-BMC 1 (2HA1).
(b) If the circuit breaker stays closed and the fault continues:
-replace the BMC-2 (1HA2).
C. After the subsequent flight, make sure that the fault does not continue.
1
R -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B206
--Feb 01/05 ---CES - Loss of the Bleed Regulator-Pressure Transducer of the Engine 2 (Detected by BMC1)
1. Possible Causes
_______________
-XDCR-BLEED REGULATED PRESS, ENG 2 (8HA2)
-BMC-1 (1HA1)
-
wiring between pin A/2 of the bleed regulated-pressure transducer (8HA2) and the ground terminal
-
wiring between pin A/1 of the bleed regulated-pressure transducer (8HA2) and the circuit breaker (2HA2)
-
wiring from the bleed regulated-pressure transducer (8HA2) to the BMC2 (1HA2
-
wiring from pin A/1 of the bleed regulated-pressure transducer (8HA2) to the circuit breaker (2HA2)
-C/B-BMC 2 (2HA2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 36-11-16-000-001 Removal of the Bleed Regulated Pressure Transducer (8HA1,8HA2) AMM 36-11-16-400-001 Installation of the Bleed Regulated Pressure
Transducer (8HA1,8HA2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) ASM 36-11/02
3. Fault Confirmation
__________________
A. Test
(1) Not Applicable
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU AIR BLEED/ENG 2/MONG 2HA2 Z22
1
R -EFF : ALL
-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page B207
--Feb 01/05 ---CES -
B. If the fault symptom is identified by the maintenance message: REG-PRESS XDCR 8HA2
-do a check of the status of the circuit breaker (2HA2).
(1) If the circuit breaker is closed:
-do a check for 28VDC at pin A/1 of the bleed regulated-pressure transducer (8HA2) (Ref. ASM 36-11/02).
(a) If there is no 28VDC:
-do a check for ground at pin A/2 of the bleed regulated-pressure transducer (8HA2).
1_ If there is no ground signal:
- repair the wiring between pin A/2 of the bleed
regulated-pressure transducer (8HA2) and the ground
terminal.
2 If there is a ground signal:
_
-do a check of the wiring between pin A/1 of the bleed regulated-pressure transducer (8HA2) and the circuit breaker (2HA2).
a If there is no continuity:
_ -repair the above wiring.
b If there is continuity:
_ -replace the circuit breaker (2HA2).
3 If the fault continues:
_
-make sure that there is a 0 psig output signal (0.9VDC) on the BMC2 (1HA2) connector between pins AA/11B and AA/12B.