-disconnect the LOOP CONTROLLER (9240SI) from the BMC1 connector
-install the BMC1 (1HA1) (Ref. AMM TASK 36-11-34-400-001)
-refer to Para. 4.C.
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 207
--Feb 01/03R ---CES -
C. After the subsequent flight, make sure that the fault does not continue.
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 208
--Feb 01/03R ---CES -
Air Leak in the Engine 2 Pylon
1. Possible Causes
_______________
-BMC-2 (1HA2)
-CABLE-CONNECTING, ENG 2 PYLON (2HF2)
-SNSG ELEM-OVHT, ENG 2 PYLON (1HF2)
-CABLE ASSY (3HF2)
-ducts
-seals
-
wiring between the pin 6B of the BMC2 connector (1HA2-AA) and the cable 2HF2
-
wiring between the pin 5B of the BMC2 connector (1HA2-AA) and the cable 3HF2
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
9240SI 1 LOOP CONTROLLER
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2)
AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2)
AMM 36-22-15-000-001 Removal of the Pylon Overheat Sensing Element (1HF1,
1HF2) AMM 36-22-15-400-001 Installation of the Pylon Overheat Sensing Element (1HF1, 1HF2) ASM 36-22/01
3. Fault Confirmation
__________________
A. Test
(1)
Start the APU.
(2)
On the AIR control panel 30VU, push the APU BLEED pushbutton switch.
1
-EFF : ALL
-∞∞36-22-00∞∞∞∞∞∞∞∞∞∞Page 209
--Feb 01/03R ---CES -
4. Fault Isolation
_______________
A. If the fault is confirmed (ENG BLEED LEAK warning):
-do a leakage check of the ducting.
(1)
If the duct is cracked/damaged:
-replace the defective ducts.
(2)
If there are leaks on the seals:
-replace the defective seals.
NOTE : If there are no air leaks, replace the seals (to prevent
____ leaks).
B. If no leak warning comes into view:
-remove the BMC2 (1HA2) (Ref. AMM TASK 36-11-34-000-001)
- on the shelf 96VU, connect the LOOP CONTROLLER (9240SI) between the connector 1HA1-AA/6B and the ground (Ref. ASM 36-22/01)
-do a check of the impedance read on the LOOP CONTROLLER (9240SI).
(1)
If the impedance is more than 3 KOhms:
-disconnect the LOOP CONTROLLER (9240SI) from the BMC2 connector
-replace the BMC-2 (1HA2) which is removed (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
-refer to Para. 4.C.
(2)
If the impedance is less than 3 KOhms: