• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 23:25来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

AMM 36-11-15-000-001 Removal of the Bleed Transferred Pressure Transducer (7HA1,7HA2) AMM 36-11-15-400-001 Installation of the Bleed Transferred Pressure
 Transducer (7HA1,7HA2) AMM 36-11-34-000-001 Removal of the BMC (1HA1, 1HA2) AMM 36-11-34-400-001 Installation of the BMC (1HA1, 1HA2) ASM 36-11/01
 3. Fault Confirmation
__________________
 A. Not applicable.
 4. Fault Isolation
_______________
 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/ENG 1/MONG 2HA1 D11
 1
 -EFF : ALL


-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 235
 --Feb 01/05R ---CES -


R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-228, 301-302,

 B. If the fault symptom is identified by the Class 3 maintenance message: 36-11-15 DRIFT TRANSF-PRESS XDCR 7HA1
 -do a check of the status of the circuit breaker (2HA1).
 (1) If the circuit breaker is closed:
 -do a check for 28VDC at pin A/1 of the bleed transferred-pressure transducer (7HA1) (Ref. ASM 36-11/01).
 (a) If there is no 28VDC:
 -do a check for ground at pin A/2 of the bleed transferred-pressure transducer (7HA1).
 1_ If there is no ground:
 - repair the wiring between pin A/2 of the bleed
 transferred-pressure transducer (7HA1) and the ground
 terminal.

 2 If there is ground:
_
 -do a check of the wiring between pin A/1 of the bleed transferred-pressure transducer (7HA1) and the circuit breaker (2HA1).
 a If there is no continuity:
_ -repair the above wiring.
 b If there is continuity:
_ -replace the circuit breaker (2HA1).
 3 If the fault continues:
_
 -make sure that there is a 0 psig output signal (0.9VDC) on the BMC1 (1HA1) connector between pins AA/14A and AA/15B.
 a If there is no 0.9VDC:
_
 -replace the XDCR-BLEED TRANSFER PRESS, ENG 1 (7HA1) (Ref. AMM TASK 36-11-15-000-001) and (Ref. AMM TASK 36-11-15-400-001).
 4 If the fault continues:
_
 -do a check and repair the wiring from the bleed transferred-pressure transducer (7HA1) to the BMC1 (1HA1), pins A/3 and A/4 to pins AA/15B and AA/14B.
 (b) If there is 28VDC:
 -replace the XDCR-BLEED TRANSFER PRESS, ENG 1 (7HA1).
 1
R -EFF : 001-049, 051-099, 101-105, 151-199,

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 236
 -201-228, 301-302, -May 01/05 ---CES -


 (2) If the circuit breaker is open:
 -close the circuit breaker.
 (a) If the circuit breaker trips:
 -replace the BMC-1 (1HA1) (Ref. AMM TASK 36-11-34-000-001) and (Ref. AMM TASK 36-11-34-400-001).
 1 If the fault continues:
_
 -do a check for a short to ground at the wiring from pin A/1 of the bleed transferred-pressure transducer (7HA1) to the circuit breaker (2HA1).
 a If there is a short to ground:
_ -repair the related wiring.
 b If there is no short to ground:
_
 -replace the C/B-BMC 1 (2HA1).
 (b) If the circuit breaker stays closed and the fault continues:
 -replace the BMC-1 (1HA1).
R **ON A/C 106-149, 229-299, 303-399, 401-499,
 B. If the fault symptom is identified by the maintenance message TRANSF-PRESS XDCR 7HA1:
 -do a check of the status of the circuit breaker (2HA1).
 (1) If the circuit breaker is closed:
 -do a check for 28VDC at pin A/1 of the bleed transferred-pressure transducer (7HA1) (Ref. ASM 36-11/01).
 (a) If there is no 28VDC:
 -do a check for ground at pin A/2 of the bleed transferred-pressure transducer (7HA1).
 1 If there is no ground:
_
 -repair the wiring between pin A/2 of the bleed transferred-pressure transducer (7HA1) and the ground terminal.
 2 If there is ground:
_
 -do a check of the wiring between pin A/1 of the bleed transferred-pressure transducer (7HA1) and the circuit breaker (2HA1).
 a If there is no continuity:
_ -repair the above wiring.
 b If there is continuity:
_
 -replace the circuit breaker (2HA1).
 1 -EFF : ALL

-∞∞36-11-00∞∞∞∞∞∞∞∞∞∞Page 237
 --Aug 01/05 ---CES -


R  3_  If the fault continues:
R  - make sure that there is a 0 psig output signal (0.9VDC) on 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 PNEUMATIC(31)