 (5) Open the access doors 195BB, 196BB. 

R  EFF : 001-049, 051-099, 101-105, 151-156, 53-31-00Page A601 201-208, May 01/05
 CES


 Subtask 53-31-00-110-077

 B. Cleaning Procedure
 WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE
_______ MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
 WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK
_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
 (1) Clean the inspection area with CLEANING AGENTS (Material No. 11-004) and a lint free cloth , if necessary. Make sure the area is dry before you continue.
 4. Procedure
_________
 Subtask 53-31-00-210-075
 A. Detailed Visual Inspection Procedure
 (Ref. Fig. 622/TASK 53-31-00-991-031)

 (1) Do a detailed visual inspection of the riveted area of the keel beam side panel at the attachment to the center wing box, LH and RH, for cracks.
 NOTE : If required, for information on repair procedures for cracks,
____ refer to the ASRM miscellaneous structure (Ref. ASRM 53-31-29-201).
R  EFF : 001-049, 051-099, 101-105, 151-156, 53-31-00Page A602 201-208, May 01/05
 CES


 Riveted Area of Keel Beam Side Panel at Attachment to Center Wing Box, LH/RH Figure 622/TASK 53-31-00-991-031
R  EFF : 001-049, 051-099, 101-105, 151-156, 53-31-00Page A603 201-208, May 01/05
 CES  5. Close-up


________
 Subtask 53-31-00-410-083

 A. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
R  (2) Install the access panels 191KB, 192KB, 195AB and 196AB (Ref. TASK 53-35-13-400-002).
 (3)
 Close the access doors 195BB and 196BB.

 (4)
 Remove the access platform(s).

 (5)
 Close the MLG doors (Ref. TASK 32-12-00-410-001).

 (6)
 Remove the warning notice(s).

 (7)
 Remove the ground support and maintenance equipment, the special and standard tools and all other items.


R  EFF : 001-049, 051-099, 101-105, 151-156, 53-31-00Page A604 201-208, May 01/05
 CES  **ON A/C ALL


 TASK 53-31-00-210-027
 Detailed Visual Inspection of Lower Skin of Longitudinal Lap Joint at Stringer 18 LH and Stringer 18 RH, in Runout Area at FR42, Internal
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 533138-01
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific lint free cloth
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-004 USA MIL-T-81533
 1.1.1TRICHLOROETHANE (METHYL CHLOROFORM)
 (Ref. 20-31-00)
 C. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
 Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
 the External Power 25-23-43-000-001 Removal of the Upper Sidewall Panel(s) 25-23-43-400-001 Installation of the Upper Sidewall Panel(s) 25-80-00-000-001 Removal of the Insulation Blankets 25-80-00-400-001 Installation of the Insulation Blankets ASRM 53-00-11-201 (for corrective action)
 EFF : ALL 53-31-00Page A605

May 01/04
R
 CES


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION -------------------------------------------------------------------------------
ASRM 53-00-13-201 (for corrective action) ASRM 53-31-11-101 (for corrective action) 53-31-00-991-029 Fig. 623
 3. Job Set-up
__________
 Subtask 53-31-00-861-055
 A. Energize the ground service network
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUSELAGE 机身2(68)