R  **ON A/C 151-199, 401-499,
 53-31-00-991-017-A Fig. 615A 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 3. Job Set-up
__________
 Subtask 53-31-00-010-068
 A. Get Access
 (1)
 Remove the emergency exit hatches (Ref. TASK 52-21-11-000-001).
 (2)
 Clean the inspection area with CLEANING AGENTS (Material No. 11-002) and a lint-free cloth where necessary.
 WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THE
_______
 SPECIAL MATERIAL.
 THIS MATERIAL IS DANGEROUS.
 WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
 4. Procedure
_________
 **ON A/C 001-049, 051-099, 101-149, 201-299,
 (Ref. Fig. 615/TASK 53-31-00-991-017) 
R  EFF : 001-049, 051-099, 101-149, 151-199, 53-31-00Page 672 201-299, 401-499, Aug 01/05
 CES
 Upper and Lower Corners of the Emergency Exit Hatch-Cutouts Figure 615/TASK 53-31-00-991-017 
R EFF : 001-049, 051-099, 101-149, 201-299, 53-31-00Page 673 May 01/05
 CES
R  **ON A/C 151-199, 401-499,
 (Ref. Fig. 615A/TASK 53-31-00-991-017-A) R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
 Subtask 53-31-00-210-066
 A. Inspection
 (1) Examine the skin cutouts at the upper and lower corners of the emergency exit hatches for:
 -cracks,
 -corrosion,
 NOTE : If necessary, refer to the ASRM (Ref. ASRM 53-31-11-101) for
____
 the correct repair procedure.
 5. Close-up
________
 Subtask 53-31-00-410-064
 A. Close Access
 (1)
 Install the emergency exit hatches (Ref. TASK 52-21-11-400-001).
 (2)
 Remove the ground support and maintenance equipment, the special and standard tools and all other items.
R  EFF : 001-049, 051-099, 101-149, 151-199, 53-31-00Page 674 201-299, 401-499, Aug 01/05
 CES
 Upper and Lower Corners of the Emergency Exit Hatch-Cutouts Figure 615A/TASK 53-31-00-991-017-A 
R EFF : 151-199, 401-499, 53-31-00Page 675 Aug 01/05
 CES R **ON A/C ALL
 TASK 53-31-00-210-018
 Detailed Visual Inspection of Skin in Circumferential Splice and Stringer Coupling Area at FR35, from STGR10, LH/RH to Crown Centerline, External Surface
 1.
 Reason for the Job
__________________
 Refer to the MPD TASK: 533121-01
 2.
 Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE  QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific lint-free cloth
 No specific warning notice
 No specific access platform 5.5 m (18 ft. 1 in.)
 B. Consumable Materials
 -------------------------------------------------------------------------------
 