• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 08:47来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (1)
 Do a general visual inspection of the cutout of the forward cargo-compartment door. This inspection is applicable to the lateral part of FR24A and FR28 that you can see.

 (2)
 Make sure that there is no:

 (a)
 Corrosion damage:

 -If you find corrosion damage, refer to the Structural Repair Manual (Ref. SRM 512200 P.Block 001) for types of corrosion, inspection, removal and corrosion protection.

 (b)
 Other damage (cracks, scratches, stress, marks, dents, bumps,...):

 


 -If you find other damage, refer to the Structural Repair Manual (Ref. SRM 511100 P.Block 001) for damage classification and corrective action.
 Subtask 53-21-00-916-062
 B. Application of the Temporary Protection (only necessary for CPCP
 (Corrosion Prevention and Control Program) MPD Task 532135-01-1)
 (Ref. Fig. 625/TASK 53-21-00-991-028)

 CAUTION : DO NOT APPLY TEMPORARY PROTECTION ON THE OXYGEN SYSTEMS.
_______ MAKE SURE THAT THE TEMPORARY PROTECTION DOES NOT GET: -ON COMPOSITE PARTS, CONTROL CABLES, PULLEYS,TEFLON BEARINGS. -ON LUBRICATED SURFACES. -IN DRAIN VALVES OR OTHER ORIFICES. TEMPORARY PROTECTION ON OR IN THESE PARTS CAN CAUSE DAMAGE.
 (1)
 Put masking paper or MASKING TAPE BONDING AND ADHESIVE COMPOUNDS (Material No. 08-074) on the equipment and fittings adjacent to the area.

 (2)
 Apply a layer of STORAGE PRESERVATION (Material No. 15-005) or STORAGE PRESERVATION (Material No. 15-006) on the inspection area.

 (3)
 Remove the masking tape or the masking paper.


 EFF : ALL 53-21-00Page A636

May 01/05
R

 CES


 Forward Cargo Door Cutout at FR24A and FR28 Figure 625/TASK 53-21-00-991-028
R  EFF : CES  ALL  53-21-00 Page A637 May 01/05 


 5. Close-up
________

 Subtask 53-21-00-410-081
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the forward cargo-compartment door 825 (Ref. TASK 52-30-00-860-002).

 (3)
 Remove the access platform(s).


 EFF : ALL 53-21-00Page A638

May 01/05
R
 CES  TASK 53-21-00-210-006


 General Visual Inspection of Forward Cargo Door Lock Fittings and Surrounding Structure, between FR 25 and FR 27A, External Portion (6 places)
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 532170-01
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  access platform 1.80 m (5 ft. 11 in.)
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific masking paper Material No. 08-074 MASKING TAPE (Ref. 20-31-00)
 Material No. 11-004  USA MIL-T-81533 1.1.1TRICHLOROETHANE (METHYL CHLOROFORM) (Ref. 20-31-00)
 Material No. 15-005  AIB TN 10138 TYPE I GRADE 2 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00)
 Material No. 15-006  AIB TN 10138 TYPE I GRADE 3 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00)
 Material No. 19-003  USA AMS 3819 LINT-FREE COTTON CLOTH (Ref. 20-31-00)
 EFF : ALL  53-21-00Page A639

May 01/05
R
 CES


 C. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
 Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
 Yellow Electric Pump SRM 511100 P.Block 001 (for corrective action) SRM 512200 P.Block 001 (for corrective action) 53-21-00-991-029 Fig. 626
 3. Job Set-up
__________
 Subtask 53-21-00-941-080
 A. Get Access
 (1)
 Put an access platform in position at the zone 132.

 (2)
 Open the forward cargo compartment door 825 (Ref. TASK 52-30-00-860-001)


 Subtask 53-21-00-110-095
 B. Cleaning of the Structure
 WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUSELAGE 机身2(12)