(2)
Open the forward emergency exit door 833 (843), (Ref. TASK 52-22-00-010-002).
(3)
Remove the door frame linings (Ref. TASK 25-23-47-000-004) (Ref. TASK 25-23-47-000-009).
(4)
Remove the door insulation.
Subtask 53-21-00-110-084
B. Cleaning of the Structure
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE
_______ MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES, GOGGLES AND A MASK.
(1) Clean the inspection area with a CLEANING AGENTS (Material No. 11-004) and a lint-free cotton cloth MISCELLANEOUS (Material No. 19-003), if necessary.
EFF : 301-399, 53-21-00Page A688
May 01/05
R
CES 4. Procedure
_________
Subtask 53-21-00-220-077
A. Inspection
(Ref. Fig. 635/TASK 53-21-00-991-037)
(1)
Do a detailed inspection of the FR35.1 and FR35.2A web and the door stop intercostals. This inspection is applicable at the junction area :
-
For the left side, between door stop No. 1 and No. 8
-
For the right side, between door stop No. 1 and No. 6.
(2)
Make sure that there is no:
(a)
Corrosion damage:
-If you find corrosion damage, refer to the Structural Repair Manual (Ref. SRM 512200 P.Block 001) for types of corrosion, inspection, removal and corrosion protection.
(b)
Other damage (cracks, scratches, stress, marks, dents, bumps,...):
-If you find other damage, refer to the Structural Repair Manual (Ref. SRM 511100 P.Block 001) for damage classification and corrective action.
5. Close-up
________
Subtask 53-21-00-410-078
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the door frame linings (Ref. TASK 25-23-47-400-004) (Ref. TASK 25-23-47-400-009).
(3)
Install the door insulation.
(4)
Close the forward emergency exit door 833 (843), (Ref. TASK 52-22-00-410-002).
(5)
Remove the access platform(s).
EFF : 301-399, 53-21-00Page A689
May 01/05
R
CES
FR35.1 and FR35.2A Web and Door Stop Intercostals Figure 635/TASK 53-21-00-991-037- 12 (SHEET 1)
R EFF : CES 301-399, 53-21-00 Page A690 May 01/05
FR35.1 and FR35.2A Web and Door Stop Intercostals Figure 635/TASK 53-21-00-991-037- 22 (SHEET 2)
R EFF : CES 301-399, 53-21-00 Page A691 May 01/05
TASK 53-21-00-220-007
Detailed Inspection of Attachment Area of FR35.1 and FR35.2A to Cabin Floor Beams, LH/RH
1. Reason for the Job
__________________
Refer to the MPD TASK: 532147-01
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 1.8 m (5 ft. 11 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-004 USA MIL-T-81533 1.1.1TRICHLOROETHANE (METHYL CHLOROFORM) (Ref. 20-31-00)
Material No. 19-003 USA AMS 3819 LINT-FREE COTTON CLOTH (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
25-54-12-000-003 Removal of the Sidewall Panels in the FWD Cargo Compartment 25-54-12-400-003 Installation of the Sidewall Panels in the FWD Cargo
Compartment 25-80-00-000-001 Removal of the Insulation Blankets 25-80-00-400-001 Installation of the Insulation Blankets 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUSELAGE 机身2(24)