1EFF : ALL 1 52-71-00Page 508 1 1 Aug 01/05 1 1 1CES 1
DOOR/OXY Page
Figure 502/TASK 52-71-00-991-001
R 1EFF : 001-049, 051-099, 101-149, 221-221, 1 52-71-00Page 509 1224-224, 228-228, 1May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
- open the circuit breakers 15WN and 2WW.
3. On the circuit breaker panel 121VU: - close the circuit breakers 2WV and 2WW. On the circuit breaker panel 49VU: - open the circuit breakers 3WV and 3WW.
R R 4. Open the four doors of the avionics compartment.
5. Open the two cargo compartment doors (Ref. TASK 52-30-00-860-001).
6. Open the bulk cargo-compartment door.
R R R R 7. Open the four passenger/crew doors and the four flaps that give access to the control handles of the emergency exits.
R 8. On the circuit breaker panel 121VU: - close the circuit breaker 15WN. - open the circuit breaker 13WN.
No change.
On the lower ECAM display unit, on theDOOR/OXY page:
-
the symbols of the four doors of the avionics compartment and the AVIONIC message come into view in amber.
On the lower ECAM display unit, on theDOOR/OXY page:
-
the symbols of the two cargo compartment doors and the CARGO message come into view in amber.
On the lower ECAM display unit, on theDOOR/OXY page:
-
the symbols for the bulk cargo-compartment door and the BULK message come into view in amber.
On the lower ECAM display unit, on the DOOR/OXY page:
-
the symbols of the four passenger/crew doors and the four emergency exits become amber. The CABIN and EMER EXIT messages come into view in amber.
No change.
1EFF : 001-049, 051-099, 101-149, 221-221, 1 52-71-00Page 510 1224-224, 228-228, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
9. Close the four passenger/crew doors and the four flaps that give access to the control handles of the emergency exits.
R R R 10. Close the four avionics compartment doors, the two cargo compartment doors (Ref. TASK 52-30-00-860-002) and the bulk cargo-compartment door.
11. On the circuit breaker panel 121VU: - close the circuit breaker 13WN.
12. On the circuit breaker panel 49VU: - close the circuit breakers 3WW and 3WV.
R **ON A/C 151-199, 401-499,
Subtask 52-71-00-710-050-B
A. Test of the Door Warning System
On the lower ECAM display unit, on theDOOR/OXY page:
-
the symbols of the fourpassenger/crew doors and the four emergency exits become green.
-
the CABIN and EMER EXIT messages go out of view.
On the lower ECAM display unit, on theDOOR/OXY page:
-
the symbols of the four avionicscompartment doors, the two cargo compartment doors and the bulk cargo-compartment door become green.
The AVIONIC, CARGO and BULK messages go out of view.
(Ref. Fig. 502A/TASK 52-71-00-991-001-B)
(Ref. TASK 52-30-00-860-001) (Ref. TASK 52-30-00-860-002).
WARNING : INSTALL A SAFETY BARRIER WHEN YOU OPEN A DOOR IF THE ACCESS
_______ PLATFORM IS NOT USED.
WARNING : DO NOT OPEN THE DOOR DURING THE ADJUSTMENT.
_______
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 52-71-00Page 511 1221-221, 224-224, 228-228, 401-499, 1Aug 01/05 1 1 1CES 1
DOOR/OXY Page Figure 502A/TASK 52-71-00-991-001-B
R 1EFF : 151-199, 401-499, 1 52-71-00Page 512 1 1 Aug 01/05 1 1 1CES 1 (1) Do the test below:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------