R
4. Procedure_________
R
Subtask 52-51-00-710-052
A. Operational Test of the Emergency Access
(1) Do this test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On Forward Attendant Panel (FAP) 120RH: In the Cockpit:
- enter the numerical emergency entry code and press the pushbutton '#' on the key pad 25MQ. - the buzzer 23MQ at the cockpitceiling panel operates.
On the COCKPIT DOOR panel 119VU: - the OPEN lamp of the indication light 22MQ flashes
On the Key Pad 25MQ: - the green LED flashes
On the Cockpit Door:
- wait for a defined period of time (adjustable between 15 sec. and 2 min.) to simulate no "flight crew reaction". - the solenoids of the electricalrelease strikes 30MQ, 31MQ and 32MQare de-energized.- the cockpit door is in the UNLOCK condition for 5 sec.
On the COCKPIT DOOR panel 119VU:
NOTE : There are two standards of the____ control unit 24MQ, P/N AR4709-1 and AR4709-3.
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
2.
On the Cockpit Door:
- open the cockpit door and close it again.
3.
On the Key Pad 25MQ:
-enter the numerical emergency entry code and press the pushbutton '#' on the keypad.
4.
On the COCKPIT DOOR panel 119VU:
-set and hold the toggle switch 26MQ to the UNLOCK position within a defined period of time (adjustable between 15 sec. and 2 min).
-
with P/N AR4709-1, the OPEN and the FAULT lamps of the indication light 22MQ come on for 5 sec.
-
with P/N AR4709-3, the OPEN lamp of the indication light 22MQ comes on for 5 sec.
On the Key Pad 25MQ:
-
the green LED come on for 5 sec.
In the cockpit:
-
the buzzer 23MQ at the cockpit ceiling 210RH stops.
On the Cockpit Door:
-
the cockpit door moves in the opendirection and back in its locked position.
In the Cockpit:
-
the buzzer 23MQ at the cockpitceiling panel operates.
On the COCKPIT DOOR panel 119VU:
-
the OPEN lamp of the indication light 22MQ flashes.
On the Key Pad 25MQ:
-
the green LED flashes
On the Cockpit Door:
-
the electrical release strikes 30MQ,31MQ and 32MQ are de-energized
-
the cockpit door is in the UNLOCKcondition.
On the Key Pad 25MQ:
-
the green LED come on.
1EFF : ALL 1 52-51-00Page 511 1 1 May 01/04R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
In the cockpit:
- the buzzer 23MQ at the cockpit
ceiling panel stops.
5. On the Cockpit Door: On the Cockpit Door:
- open the cockpit door and close - the cockpit door moves in the open
it again. direction and back in its closed
position.
6. On the COCKPIT DOOR panel 119VU: On the COCKPIT DOOR panel 119VU:
- release the toggle switch 26MQ. On the Cockpit Door:
- the toggle switch 26MQ returns to the
NORM position automatically.
On the Cockpit Door:
- the solenoids of the electrical
release strikes 30MQ, 31MQ and 32MQ
are energized.
- the cockpit door is in the LOCK
condition.
7. On the Key Pad 25MQ: In the Cockpit:
- enter the numerical emergency - the buzzer 23MQ at the cockpit
entry code and press the ceiling panel operates.
pushbutton '#' on the keypad.
On the COCKPIT DOOR panel 119VU:
- the OPEN lamp of the indication light
22MQ flashes
On the Key Pad 25MQ:
- the green LED flashes
8. On the COCKPIT DOOR panel: On the Cockpit Door:
- set and hold the toggle switch - the solenoids of the electrical
26MQ to the LOCK position release strikes 30MQ, 31MQ and 32MQ
within a defined period of time stay energized
(adjustable between 15 sec. and - the cockpit door remains locked.