-Remove the proximity switch of the avionics-compartment access door (Ref. TASK 52-71-14-000-001).
-Install this proximity switch on the applicable emergency exit (Ref. TASK 52-71-13-400-001).
(b) If the fault continues:
-Refer to the MMEL document for dispatch conditions.
R 1EFF : 151-199, 401-499, 1 52-70-00Page 426 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
TASK 52-70-00-440-003
Reactivation of the Emergency Exit Doors
1. Reason for the Job
__________________
Refer to the MMEL TASK: 52-70-01-B)
DOOR WARNINGS - Indications on ECAM DOOR
page and associated cautions on ECAM
upper display -Overwing Emergency exit
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
TSM 52410002
3. Job Set-up
__________
Subtask 52-70-00-869-052
A. Not Applicable
4. Procedure
_________
Subtask 52-70-00-810-053
A. Trouble Shooting Procedure
(1) If the applicable proximity switch was replaced by a proximity switch of the avionics-compartment access door, do the applicable trouble shooting of the avionics-compartment access door (Ref. TSM 52410002).
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 52-70-00Page 427 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
TASK 52-70-00-040-004
Visual Check to Make Sure that the Avionics-Compartment Access Doors are Correctly Closed
1. Reason for the Job
__________________
Refer to the MMEL TASK: 52-70-01-D)
DOOR WARNINGS - Indications on ECAM DOOR
page and associated cautions on ECAM
upper display -Avionics compartment
access door
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform 1.5 m (4 ft. 11 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-41-00-410-002 Close the Avionics Compartment Doors after Access
3. Job Set-up
__________ Subtask 52-70-00-010-054
A. Get Access
(1)
Put an access platform in position at the applicable avionics-compartment access door 811 or 812 or 822 or 824.
(2)
Manually open the related avionics-compartment access door 811 or 812 or 822 or 824.
1EFF : ALL 1 52-70-00Page 428 1 1 Aug 01/05R 1 1 1CES 1
4. Procedure
_________ Subtask 52-70-00-210-056
A. Visual Check to Make Sure that the Avionics-Compartment Access Door is Correctly Closed
(1)
With the door open, move the handle so as to operate the locking system.
(2)
Make sure that the locks get out of their housing and operate correctly.
(3)
Put the handle in the door open position.
(4) Close the avionics-compartment access door and lock it. Subtask 52-70-00-970-056
B. Entry in the Log Book.
(1) Make an entry in the aircraft log book to record that:
-
the AVIONICS indication is defective on the lower ECAM DU
-
the avionics-compartment access door(s) are closed and locked.
5. Close-up
________ Subtask 52-70-00-410-054
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Manually close the concerned avionics-compartment access door 811 or 812 or 822 or 824 (Ref. TASK 52-41-00-410-002).