R 1EFF : 401-499, 1 21-51-00Page 56 1 1 Aug 01/05 1 1 1CES 1
R  (5) Operation with Failures  
R  (a) Single Pack Failure  
R  When the PACK FLOW selector is set to the NORM or LO position and  
R  there is a failure in one pack, the ACSC modulates the other pack  
R  to the 120% (HI) mode. Thus the flow control valve is commanded  
R  to the fully open position.  
R  (b) Engine Fire  
R  If there is an engine fire, and you push the applicable FIRE  
R  pushbutton switch, the respective flow control valve closes. This  
R  stops the hot bleed air flow in order to prevent damage to the  
R  components of the air conditioning system and to prevent entry of  
R  smoke into the cabin.  
R  (c) Ditching  
R  In case of landing on water the DITCHING pushbutton switch must  
R  be pushed. This closes the flow control valves which prevents the  
R  entry of water into the cabin through the air conditioning  
R  system.  
R  (d) Air-Cycle Machine Compressor Overheat  
R  If the compressor of an air-cycle machine exceeds 215 deg.C  
R  (419.00 deg.F), the ACSC and flow control valve will start to  
R  reduce the pack flow independent of the flow demand till the  
R  minimum flow demand is reached.  
R  When the compressor temperature reaches 260 deg.C (500.00 deg.F)  
R  (overheats) on ground, the ACSC will shut off the pack (flow  
R  control valve is closed).  
R  (e) Pack Shut-down in the Engine-Start Sequence  
R  In the engine-start sequence (the EIU gives an engine rpm-signal  
R  of N1<50%), normally both air-packs close.  
R  To prevent the complete pack shut-down in flight because of a  
R  wrong EIU-signal, the crossbleed valve indication relay 7HV  
R  monitors the position of the Cross Bleed Valve (CBV) 6HV:  
R  - If the CBV is in the closed position, only one pack instead of  
 