PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R 122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC 2HH Y18
**ON A/C ALL
R 122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL 5HU U21
R 122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY 6HU U19
R 122VU AIR COND/RECIRC FAN/R/CTL 11HG W20
R 122VU AIR COND/RECIRC FAN/R/SPLY 3HG W18
R 122VU AIR COND/RECIRC FAN/L/CTL 2HG X20
R 122VU AIR COND/RECIRC FAN/L/SPLY 1HG X18
122VU AIR COND/AVNCS/VENT/MONG 3HQ Y17
R **ON A/C 106-149, 303-399,
R 122VU 4HH Y19
R **ON A/C 401-499,
R 122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC 53HH W22
R 122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC 55HH W21
R 122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC 49HH X22
R 122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC 51HH X21
R 122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC 56HH Y21
R 122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC 54HH Y20
122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC 50HH Y18
R
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
123VU AVNCS VENT/EXTC/FAN 2HQ AE02
**ON A/C ALL
123VU AVNCS VENT/BLOWER/FAN 1HQ AD10
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C 301-399,
123VU AVNCS VENT/EXTC/FAN 2HQ AC04
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
Subtask 21-51-00-865-055
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
122VU AIR COND/ZONE TEMP CTL/115VAC/SYS1 1HK V17
**ON A/C ALL
Subtask 21-51-00-860-060
D. Preconditioning
(1)
Do the Procedure to Start the APU or,
-
(Ref. TASK 49-00-00-860-003) or,
-
(Ref. TASK 49-00-00-860-005) or,
-
(Ref. TASK 49-00-00-860-008).
(2)
Do the preconditioning through the HP connector (Ref. TASK 12-33-21-618-001).
**ON A/C 001-049, 101-105, 151-199, 201-210,
Subtask 21-51-00-860-051-A
E. Aircraft Maintenance Configuration
(1)
Do the EIS start procedure (Ref. TASK 31-60-00-860-001).
(2)
On the AIR panel 30VU:
-
put the APU BLEED pushbutton switch to the on position (the ON legend comes on) and,
-
put the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).
(3)
Make sure that the BLEED page is shown on the ECAM lower display.
(4)
Cockpit Effects
(a) After approximately 60 seconds: - on the COND page the message ALTN MODE shows above the aircraft symbols and,
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 3(103)