PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,  
R  122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC  2HH  Y18 
 **ON A/C ALL  
R  122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL  5HU  U21  
R  122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY  6HU  U19  
R  122VU AIR COND/RECIRC FAN/R/CTL  11HG  W20  
R  122VU AIR COND/RECIRC FAN/R/SPLY  3HG  W18  
R  122VU AIR COND/RECIRC FAN/L/CTL  2HG  X20  
R  122VU AIR COND/RECIRC FAN/L/SPLY  1HG  X18 
 122VU AIR COND/AVNCS/VENT/MONG  3HQ  Y17  
R  **ON A/C 106-149, 303-399,  
R  122VU  4HH  Y19  
R  **ON A/C 401-499,  
R  122VU AIR COND/TEMP CTL SYS 2/CHAN A/115VAC  53HH  W22  
R  122VU AIR COND/TEMP CTL SYS 2/CHAN A/28VDC  55HH  W21  
R  122VU AIR COND/TEMP CTL SYS 1/CHAN A/115VAC  49HH  X22  
R  122VU AIR COND/TEMP CTL SYS 1/CHAN A/28VDC  51HH  X21  
R  122VU AIR COND/TEMP CTL SYS 2/CHAN B/28VDC  56HH  Y21  
R  122VU AIR COND/TEMP CTL SYS 2/CHAN B/115VAC  54HH  Y20 
 122VU AIR COND/TEMP CTL SYS 1/CHAN B/115VAC  50HH  Y18  
R  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499, 
 123VU AVNCS VENT/EXTC/FAN  2HQ  AE02 
 **ON A/C ALL 
 123VU AVNCS VENT/BLOWER/FAN  1HQ  AD10
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C 301-399,
 123VU AVNCS VENT/EXTC/FAN 2HQ AC04
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 Subtask 21-51-00-865-055
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
122VU AIR COND/ZONE TEMP CTL/115VAC/SYS1 1HK V17
 **ON A/C ALL
 Subtask 21-51-00-860-060
 D. Preconditioning
 (1)
 Do the Procedure to Start the APU or,
 -
(Ref. TASK 49-00-00-860-003) or,
 -
(Ref. TASK 49-00-00-860-005) or,
 -
(Ref. TASK 49-00-00-860-008).
 (2)
 Do the preconditioning through the HP connector (Ref. TASK 12-33-21-618-001).
 **ON A/C 001-049, 101-105, 151-199, 201-210,
 Subtask 21-51-00-860-051-A
 E. Aircraft Maintenance Configuration
 (1)
 Do the EIS start procedure (Ref. TASK 31-60-00-860-001).
 (2)
 On the AIR panel 30VU:
 -
put the APU BLEED pushbutton switch to the on position (the ON legend comes on) and,
 -
put the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).
 (3)
 Make sure that the BLEED page is shown on the ECAM lower display.
 (4)
 Cockpit Effects
 (a) After approximately 60 seconds: - on the COND page the message ALTN MODE shows above the aircraft symbols and,
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 3(103)