After approx. 180 seconds:
-
the left pack flow indicator moves to the LO indication area (between the LO and the 11 o'clock position).
After approx. 10 seconds:
-
the left pack flow indicator moves to the NORM position (between the 11 o'clock and the 1 o'clock position).
After approx. 35 seconds:
-
the right pack flow indicator moves to the NORM position (between the 11 o'clock and the 1 o'clock position).
R 1EFF : 301-399, 1 21-51-00Page 511 1 1 Aug 01/05 1 1 1CES 1
R **ON A/C 401-499,
R Subtask 21-51-00-710-051-D
R A. Operational Test of the Flow Control and Indicating System
R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------
R NOTE : The approximate times given in this test can be very different as____
R they are dependant upon:
R - the ambient air temperature and altitude above sea level,
R - the type and overall condition of the APU installed in the
R aircraft and,
R - the overall condition of the environmental control system.
R 1. On the panel 30VU: The OFF legend in the PACK 2 pushbutton
R - push the PACK 2 pushbutton switch comes on.
R switch to the off position.
R FOR 8HB
R On the ECAM lower display unit:
R - the right pack flow control valve
R shows GREEN and closed.
R - the left pack flow indicator is in
R the LO indication area (between the
R LO and the 11 o'clock position).
R - after approx. 20 seconds it moves to
R the HI indication area (between the 1
R o'clock and the HI position).
R 2. On the panel 30VU: On the panel 30VU:
R - push the PACK 2 pushbutton - the OFF legend in the PACK 2
R switch to the on position. pushbutton switch goes off.
R On the ECAM lower display unit:
R - the right flow control valve symbol
R shows GREEN and open.
R - the left pack flow indicator moves to
R the LO indication area (between the
R LO and the 11 o'clock position).
R After approx. 180 seconds:
R 1EFF : 401-499, 1 21-51-00Page 512 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R - the right pack flow indicator moves
R to the LO indication area (between
R the LO and the 11 o'clock position).
R After approx. 20 seconds:
R - the right pack flow indicator moves
R to the NORM position (between the 11
R o'clock and the 1 o'clock position).
R After approx. 35 seconds:
R - the left pack flow indicator moves to
R the NORM position (between the 11
R o'clock and the 1 o'clock position).
R 3. On the panel 30VU: The OFF legend in the PACK 1 pushbutton
R - push the PACK 1 pushbutton switch comes on.
R switch to the off position.
R FOR 11HB
R On the ECAM lower display unit:
R - the left pack flow control valve
R shows GREEN and closed.
R - the right pack flow indicator is in
R the LO indication area (between the
R LO and the 11 o'clock position).
R - after approx. 10 seconds it moves to
R the HI indication area (between the 1
R o'clock and the HI position).
R 4. On the panel 30VU: On the panel 30VU:
R - push the PACK 1 pushbutton - the OFF legend in the PACK 1
R switch to the on position. pushbutton switch goes off.
R On the ECAM lower display unit:
R - the left flow control valve symbol
R shows GREEN and open.
R - the right pack flow indicator moves
R to the LO indication area (between
R the LO and the 11 o'clock position).
R After approx. 180 seconds:
R - the left pack flow indicator moves to