 - on the upper ECAM display the message, COND ZONE REGUL FAULT, is shown.

R **ON A/C 051-099, 106-149, 211-299, 301-399,
 Subtask 21-51-00-860-051
 E. Aircraft Maintenance Configuration
 (1)
 Do the EIS start procedure (Ref. TASK 31-60-00-860-001).

 (2)
 Make sure that the ADIRU is activated (Ref. TASK 34-10-00-860-002).

 (3)
 On the AIR panel 30VU:

 -
put the APU BLEED pushbutton switch to the on position (the ON legend comes on) and,

 -
put the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).

 

 (4)
 Make sure that the BLEED page is shown on the ECAM lower display.


R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-51-00Page 505 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1 (5) Cockpit Effects


 (a) After approximately 60 seconds: - on the COND page the message ALTN MODE shows above the aircraft symbols and,
 - on the upper ECAM display the message, COND ZONE REGUL FAULT, is shown.

R **ON A/C 401-499,
 Subtask 21-51-00-860-051-C
 E. Aircraft Maintenance Configuration
 (1)
 Do the EIS start procedure (Ref. TASK 31-60-00-860-001).

 (2)
 Make sure that the ADIRU is activated (Ref. TASK 34-10-00-860-002).

 (3)
 On the AIR panel 30VU:

 -
put the APU BLEED pushbutton switch to the on position (the ON legend comes on) and,

 -
put the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).

 

 (4)
 Make sure that the BLEED page is shown on the ECAM lower display.


R 1EFF : 051-099, 106-149, 211-299, 301-399, 1 21-51-00Page 506 1401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL


 4. Procedure
_________

R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
 Subtask 21-51-00-710-051-A
 A. Operational Test of the Flow Control and Indicating System
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
NOTE : The approximate times given in this test can be very different as
____
 they are dependant upon:

 -
the ambient air temperature and altitude above sea level,

 -
the type and overall condition of the APU installed in the aircraft and,

 -
the overall condition of the environmental control system.


 1. On the panel 30VU: - push the PACK 2 pushbutton switch to the off position. The OFF legend in the PACK 2 pushbuttonswitch comes on.
 FOR 8HB
 On the ECAM lower display unit: - the right pack flow control valve shows GREEN and closed.
 - the left pack flow indicator is in the LO indication area (between the LO and the 11 o'clock position). - after approx. 10 seconds it moves to the HI indication area (between the 1 o'clock and the HI position).
 2. On the panel 30VU: - push the PACK 2 pushbutton switch to the on position.  On the panel 30VU:- the OFF legend in the PACK 2pushbutton switch goes off.
 On the ECAM lower display unit: - the right flow control valve symbol shows GREEN and open. 

R 1EFF : ALL 1 21-51-00Page 507 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-
the left pack flow indicator moves to the LO indication area (between the LO and the 11 o'clock position).

 After approx. 180 seconds:

 -
the right pack flow indicator moves to the LO indication area (between the LO and the 11 o'clock position).

 After approx. 10 seconds:

 -
the right pack flow indicator moves to the NORM position (between the 11 o'clock and the 1 o'clock position).

 After approx. 35 seconds:

 -
the left pack flow indicator moves to the NORM position (between the 11 o'clock and the 1 o'clock position).


 3. On the panel 30VU:  The OFF legend in the PACK 1 pushbutton
 -push the PACK 1 pushbutton switch comes on.
 switch to the off position.
 FOR 11HB

 On the ECAM lower display unit:
 -
the left pack flow control valve shows GREEN and closed.

 -
the right pack flow indicator is in the LO indication area (between the LO and the 11 o'clock position).


 -after approx. 10 seconds it moves to the HI indication area (between the 1 o'clock and the HI position).
 4. On the panel 30VU:  On the panel 30VU:
 