R **ON A/C 051-099, 106-149, 211-299, 301-399,
Subtask 21-51-00-860-051
E. Aircraft Maintenance Configuration
(1)
Do the EIS start procedure (Ref. TASK 31-60-00-860-001).
(2)
Make sure that the ADIRU is activated (Ref. TASK 34-10-00-860-002).
(3)
On the AIR panel 30VU:
-
put the APU BLEED pushbutton switch to the on position (the ON legend comes on) and,
-
put the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).
(4)
Make sure that the BLEED page is shown on the ECAM lower display.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-51-00Page 505 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1 (5) Cockpit Effects
(a) After approximately 60 seconds: - on the COND page the message ALTN MODE shows above the aircraft symbols and,
- on the upper ECAM display the message, COND ZONE REGUL FAULT, is shown.
R **ON A/C 401-499,
Subtask 21-51-00-860-051-C
E. Aircraft Maintenance Configuration
(1)
Do the EIS start procedure (Ref. TASK 31-60-00-860-001).
(2)
Make sure that the ADIRU is activated (Ref. TASK 34-10-00-860-002).
(3)
On the AIR panel 30VU:
-
put the APU BLEED pushbutton switch to the on position (the ON legend comes on) and,
-
put the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).
(4)
Make sure that the BLEED page is shown on the ECAM lower display.
R 1EFF : 051-099, 106-149, 211-299, 301-399, 1 21-51-00Page 506 1401-499, 1Aug 01/05 1 1 1CES 1 **ON A/C ALL
4. Procedure
_________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
Subtask 21-51-00-710-051-A
A. Operational Test of the Flow Control and Indicating System
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
NOTE : The approximate times given in this test can be very different as
____
they are dependant upon:
-
the ambient air temperature and altitude above sea level,
-
the type and overall condition of the APU installed in the aircraft and,
-
the overall condition of the environmental control system.
1. On the panel 30VU: - push the PACK 2 pushbutton switch to the off position. The OFF legend in the PACK 2 pushbuttonswitch comes on.
FOR 8HB
On the ECAM lower display unit: - the right pack flow control valve shows GREEN and closed.
- the left pack flow indicator is in the LO indication area (between the LO and the 11 o'clock position). - after approx. 10 seconds it moves to the HI indication area (between the 1 o'clock and the HI position).
2. On the panel 30VU: - push the PACK 2 pushbutton switch to the on position. On the panel 30VU:- the OFF legend in the PACK 2pushbutton switch goes off.
On the ECAM lower display unit: - the right flow control valve symbol shows GREEN and open.
R 1EFF : ALL 1 21-51-00Page 507 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-
the left pack flow indicator moves to the LO indication area (between the LO and the 11 o'clock position).
After approx. 180 seconds:
-
the right pack flow indicator moves to the LO indication area (between the LO and the 11 o'clock position).
After approx. 10 seconds:
-
the right pack flow indicator moves to the NORM position (between the 11 o'clock and the 1 o'clock position).
After approx. 35 seconds:
-
the left pack flow indicator moves to the NORM position (between the 11 o'clock and the 1 o'clock position).
3. On the panel 30VU: The OFF legend in the PACK 1 pushbutton
-push the PACK 1 pushbutton switch comes on.
switch to the off position.
FOR 11HB
On the ECAM lower display unit:
-
the left pack flow control valve shows GREEN and closed.
-
the right pack flow indicator is in the LO indication area (between the LO and the 11 o'clock position).
-after approx. 10 seconds it moves to the HI indication area (between the 1 o'clock and the HI position).
4. On the panel 30VU: On the panel 30VU: