apply the PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-001B) to the areas of the dried sealant.
 (Ref. Fig. 502/TASK 21-31-00-991-004)
 (b) FOR 12HL
 -the pin 2 on the electrical connector 12HL-AC and a good conductive surface on the aircraft structure.
 -measure the resistance value and make sure that it is not more than the maximum allowed value.
 -you must do the bonding of the bonding point 6582VN/DC2 (Ref. TASK 20-28-00-912-004) if the resistance value is more than the allowed value.
 NOTE : For this application, when you do the bonding you must:
____
 -apply the SEALANTS (Material No. 09-013) to the necessary areas and allow it to fully dry then, 
R 1EFF : ALL 1 21-31-00Page 533 1 1 Feb 01/04 1 1 1CES 1
 Return Ground Connections - Earthing Points 
 Figure 502/TASK 21-31-00-991-004- 12 (SHEET 1) 
 1EFF :  ALL  1  21-31-00 Page 534  
1  1  Feb 01/98 
 1  1 
 1CES  1
 Return Ground Connections - Earthing Points 
 Figure 502/TASK 21-31-00-991-004- 22 (SHEET 2) 
 1EFF :  ALL  1  21-31-00 Page 535  
1  1  Feb 01/98 
 1  1 
 1CES  1
 -apply the PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-001B) to the areas of the dried sealant.
 (Ref. Fig. 502/TASK 21-31-00-991-004)
 (c)
 FOR 10HL1
 (d)
 FOR 10HL2
 1_ the pin J on the electrical connector 10HL-A and a good 
 conductive surface on the aircraft structure. 
 - measure the resistance value and make sure that it is not 
 more than the maximum allowed value. 
 - you must do the bonding of the bonding point 6587VN/DC1 
 (Ref. TASK 20-28-00-912-004) if the resistance value is more 
 than the allowed value. 
 NOTE : For this application, when you do the bonding you must:____ 
 - apply the SEALANTS (Material No. 09-013) to the 
 necessary areas and allow it to fully dry then, 
 - apply the PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) 
 (Material No. 07-001B) to the areas of the dried 
 sealant. 
 2_ the pin J on the electrical connector 10HL-D and a good 
 conductive surface on the aircraft structure. 
 - measure the resistance value and make sure that it is not 
 more than the maximum allowed value. 
 - you must do the bonding of the bonding point 6587VN/DC1 
 (Ref. TASK 20-28-00-912-004) if the resistance value is more 
 than the allowed value. 
 NOTE : For this application, when you do the bonding you must:____ 
 - apply the SEALANTS (Material No. 09-013) to the 
 necessary areas and allow it to fully dry then, 
 - apply the PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) 
 (Material No. 07-001B) to the areas of the dried 
 sealant. 
 (Ref. Fig. 502/TASK 21-31-00-991-004)
 1 the pin J on the electrical connector 10HL-B and a good
_ conductive surface on the aircraft structure.
 -measure the resistance value and make sure that it is not more than the maximum allowed value.
 -you must do the bonding of the bonding point 6582VN/DC2 (Ref. TASK 20-28-00-912-004) if the resistance value is more than the allowed value.
 1EFF : ALL 1 21-31-00Page 536 1 1 Nov 01/99R 1 1 1CES 1
 2 the pin H on the electrical connector 10HL-E and a good
_ conductive surface on the aircraft structure.
 -measure the resistance value and make sure that it is not more than the maximum allowed value.
 -you must do the bonding of the bonding point 6582VN/DC2 (Ref. TASK 20-28-00-912-004) if the resistance value is more than the allowed value.
 NOTE : For this application, when you do the bonding you must:
____
 -
apply the SEALANTS (Material No. 09-013) to the necessary areas and allow it to fully dry then,
 -
apply the PAINTS FOR DETAIL (INTERNAL AND EXTERN AL) (Material No. 07-001B) to the areas of the dried sealant.
 (Ref. Fig. 502/TASK 21-31-00-991-004)
 5. Close-up
________
 Subtask 21-31-00-860-067
 A. Aircraft Maintenance Configuration
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 3(20)