A. Energize the aircraft electrical circuits. (Ref. TASK 24-41-00-861-002) Subtask 21-51-00-010-056
 B. Get Access
 (1)
 Remove the access panel (Ref. TASK 53-35-13-000-002):
 (a) For PACK 1
 -191KB.
 (2)
 For PACK 2
 -192KB,
 Subtask 21-51-00-941-055
 C. Safety Precautions
 (1)
 On the panel 30VU:
 (a)
 Make sure that:
 -
the APU BLEED pushbutton switch is in the off position (the ON legend is off) and,
 -
the ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
 (b)
 Put a warning notice in position to tell persons not to operate these switches.
 (2)
 On the HP ground connector put a warning notice in position to tell persons not to supply the ground air.
R 1EFF : 106-149, 303-399, 401-499, 1 21-51-00Page 413 1 1 Aug 01/05 1 1 1CES 1 Subtask 21-51-00-860-057
 D. ECAM Warning Check before Deactivation
 (1) On the Upper ECAM E/WD make sure that the warnings which follow are not shown:
 -
AIR PACK 1 REGUL FAULT or AIR PACK 2 REGUL FAULT,
 -
AIR COND CTL 1-A FAULT or AIR COND CTL 2-A FAULT,
 -
AIR COND CTL 1-B FAULT or AIR COND CTL 2-B FAULT.
 4. Procedure
_________
 Subtask 21-51-00-040-051
 A. Deactivation of the Air Conditioning Pack WARNING : DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY
_______
 COOL TO PREVENT BURNS.
 (1)
 For PACK 1
(a) Push the PACK 1 pushbutton switch to the off position (the OFF legend comes on).
 (2)
 For PACK 2
 (a) Push the PACK 2 pushbutton switch to the off position (the OFF legend comes on).
 (3) On the related flow control unit 23HB (24HB): R **ON A/C 401-499,
 (Ref. Fig. 402/TASK 21-51-00-991-006) R **ON A/C 106-149, 303-399, 401-499,
 (a)
 Remove the blanking cap (1) from the position (A). NOTE : This will vent the pack flow-control unit and close the
____
 butterfly valve.
 (b)
 Make sure that the forked valve-position indicator lever (2) is at the CLOSED position.
R 1EFF : 106-149, 303-399, 401-499, 1 21-51-00Page 414 1 1 Aug 01/05 1 1 1CES 1
 Pack FlowControl Unit - Component Location
 Figure 402/TASK 21-51-00-991-006
R 1EFF : 401-499, 1 21-51-00Page 415 1 1 Aug 01/05 1 1 1CES 1
 (c)
 Install the blanking cap (1) between the forks of the valve-position indicator lever (2) and on the screwed boss (B).
 (d)
 Safety the blanking cap (1) with corrosion-resistant steel lockwire 0.8 mm (0.0314 in.) dia.
 5. Close-up
________ Subtask 21-51-00-410-056
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.
 (2)
 Install the access panel (Ref. TASK 53-35-13-400-002) :
 (a)
 For PACK 1
-191KB.
 (b)
 For PACK 2
 -192KB,
 (3)
 Remove the warning notice(s).
 (4)
 Record the deactivation of the air conditioning pack in the aircraft technical log book.
 Subtask 21-51-00-862-055
 B. De-energize the aircraft electrical circuits. (Ref. TASK 24-41-00-862-002) 
R 1EFF : 106-149, 303-399, 401-499, 1 21-51-00Page 416 1 1 Aug 01/05 1 1 1CES 1 TASK 21-51-00-440-001-A
 Reactivation of the Air Conditioning Pack
 WARNING : MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM
_______ FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
 NOTE : The procedure is the same for both packs 10HM (11HM)
____
 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 21-52-01
 Air cooling system
 Air conditioning pack
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 53-35-13-000-002 Removal of the Quick-Release Access Panels from the Belly Fairing Structure 53-35-13-400-002 Installation of the Quick-Release Access Panels on the Belly Fairing Structure TSM ATA 21 (for corrective action)
 